Mica,Band,Heater,Heaters

Mica Band Heater (Heaters)


Process Controls Index


  Mica Band Heater (Heaters)

Mica Band Heater - All applications must consider the suitability of the diameter fit, mounting method, the correct watt density and appropriate terminal protection.

Mica Band Heater (Heaters)

Construction | Leads | Terminals

Mica Band Heater (Heaters) - Construction

2 Piece Construction
Ease of installation in difficult locations. Recommended for diameters larger than 15". Available with any termination or clamping styles.

Back to Top

Built-in Strap
Barrel nuts provide secure and strong clamping. Also availble in spring loaded designs for larger diameters.

Back to Top

Expandable or Hinged
One piece construction used where heater cannot be slid over the barrel or die. Two sets of terminals required. All terminations available.

Back to Top

Bent Up Flange
Available with any termination style and is only recommended for narrower designs.

Back to Top

Holes and Cutouts
Allow for installation of thermocouples and transducers and give clearance for mounting bolts.

Back to Top

Separate Strap
Available in all sizes and configurations. Built-in straps are recommended wherever possible. Typically used in smaller diameters.

Back to Top

Mica Band Heater (Heaters) - Leads
W1

Nozzle Style
Fiberglass leads 12" long is standard.

Back to Top

W2

Nozzle Style
Fiberglass leads with metal overbraid 12" long is standard.

Back to Top

W3

Fiberglass Leads with Metal Braid
Exiting from the edge at 180 degrees from the gap.

Back to Top

W4

Fiberglass Leads with Armor Cable
Specify location and length of leads at time of order.

Back to Top

W5

Fiberglass Leads with Metal Braid
Specify location and length of leads at time of order.

Back to Top

W6

Fiberglass Leads with Protective Sleeve
Specify location and length of leads at time of order.

Back to Top

Mica Band Heater (Heaters) - Terminals
T1

10-32 Threaded Terminals
Minimum width required 7/8"

Back to Top

T2

10-32 Threaded Terminals
Minimum width required 7/8"
Specify location at time of order.

Back to Top

T3

10-32 Threaded Terminals
Minimum width required 2.00"
Specify location at time of order.

Back to Top

CTP

Ceramic Terminal Covers
Available on all threaded terminals. Covers available separately.

Back to Top

TB

Sheet Metal Terminal Box
Available with T2 and T3 threaded terminals.

Back to Top

EP

90 Degree European Plug
Also available straight out
Specify location at time of order.

Back to Top



Site Designed & Maintained by Panther Marketing & Design