Solid-State Output TBL Miniature Timers
Solid-State Output TBL Miniature Timers
|
|
 |
TBL Miniature Timers
TBL timers are solid-state output units with digital timing and come in a 15/8" square case. They are available for 8-40 VdC. Ease of installation and hook-up is a primary design benefit. All models with integral time adjustment knob or factory-fixed time require only three connections. |
Timing Mode
Application of input voltage to the timer energizes the load and starts the time delay. At the end of the time delay, the load is de-energized. Removal and re-application of input voltage re-sets the timer.
|
 |
|
FEATURES |
-
Digital timing, solid-state “mosfet” output
-
1 Amp current load handling
-
10 Amps 100 ms (millisecond) surge handling
-
Wide DC voltage range
-
1% Repeat accuracy
-
Virtually unlimited time ranges
-
Factory-fixed or variable-timing adjustment
- Totally encapsulated for protection from harsh environments
|
-
O-ring sealed exposed controls
-
Single #6 screw mounting through center mounting hole
-
Standard 6.35mm (.250") quick connect blade terminals
- 100% Operational testing before shipping
|
| BASIC WIRING AND DIMENSIONS |
 |
| SPECIFICATIONS |
|
Repeat Accuracy: ±0.1%under fixed conditions
Time Ranges: 0.1 sec. to 24 hours (1 sec., 10 sec., 100 sec., and 1000 secs. are standard) Special time ranges available on request.
Reset/Recycle Time: 100 milliseconds
Tolerances: Fixed: ±10% of normal time (optional: -±5%,±1%) Variable: -0%, +15% Limit:-10% at minimum time
Recycle Effect: None
Temperature Ranges:
- Storage: -40°C to +85°C
- Operating: -25°C to +85°C
Life Expectancy: No predictable failure if used within operating parameters |
Protection:
- Polarity Protection: All DC units have reverse polarity protection
- Transient Protection: 18 joules
- Dielectric Strength: 1800V RMS 60 Hz
Power Requirement: .25 watts max.
Weight: 3 oz. (85g) maximum
Solid-State Output: SPST (N.C.)
Load Current: 1 amp continuus, 10 amps 100 ms surge
Time Cycle Interrupt: Resets timer to original state (input Voltage Break)
|
| SELECTION PROCEDURE |
| Mode of Operation |
Series |
Input Voltage |
Time Ranges |
Time Adjustment Method |
| Interval On Delay |
TBL |
1 8-40 VDC
|
VARIABLE TIME PERIODS |
- Variable, integral, knob on timer.
- Fixed, internal, factory set
|
0001 .1 to 1 sec.
0001 0.5 to 1 sec.
0010 .1 to 10 sec.
0100 1 to 100 sec.
1000 10 to 1000 sec. Any range up to 24 hours avaialble on special order |
| FIXED TIME PERIODS |
Specify time in seconds(S) or hours(H)
Examples: 400S is 400 secs 05H5 is 5.5 hours |
|