Cube Relay, Delay On Make Timers, TGPSL Timers, Airotronics


Cube Relay Single Shot Timers - TGPSL Timer

Cube Relay Single Shot Timers - TGPSL Timers
TGPSL Timers

TGPSL series Cube Relay Single Shot timers are a unique combination of digital CMOS timing circuitry with a relay output in a compact 2" x 2" configuration. For users of solid-state timers, these units provide the same functional performance as plug-in relay timers, but at significant cost savings. The TGPSL has an external control switch connected to (+) or hot.


Timing Mode

Power must be applied to the input voltage terminals continuously. Upon closing and opening an external initiate switch, the load is instantaneously energized and the time delay cycle starts. When the delay period expires, the timer will reset to its original position and the timer is ready for another cycle.

  • High current carrying capacity up to 10 amps
  • Transient protected
  • 100% Load isolation
  • No leakage in N.O. position
  • No heat sinking required
  • Available in any time delay period required
  • Digital CMOS timing
  • No minimum load required
  • Totally encapsulated for protection from harsh environments
  • 100% Operational testing before shipping
Input Voltage:
  • VDC: 12,24 or 48
  • VAC: 24,48,120 or 230,50/60 Hz
Time Delay:
  • Timing Mode: Single Shot on Break
  • Type: Digital CMOS
  • Time Range: 0.2 seconds to 24 hours
  • Time Adjustment: Factory fixed time period; Variable, with adjustments on timer, or terminals for external resistors or potentiometer

Repeatability: ±0.5%

Setting Accuracy:
  • Fixed time periods: ±10% of nominal time
  • Variable time ranges:
    +15% -5% max. time, -10% min. time
Reset Time/Recycle Time: 25 milliseconds

Initiate Time: 6 milliseconds or less

Relay Output:
  • Form: Standard - SPST N.O.
    Optional - SPST N.C., SPDT
Relay Life Expectancy:
  • Mechanical: 20 million operations
  • Electrical: 100,000 operations at max. load
  • Contact Material: Silver nickel, gold plated, or silver cadmium oxide
  • Polarity Protection: All DC units have reverse polarity protection
  • Transient Protection: 18 joules
  • Dielectric Strength: 1800V RMS 60 Hz
Temperature Ranges:
  • Storage: -40°C + 85°C
  • Operating: -25°C to +85°C
Physical Data:
  • Mounting: Surface with one #8 screw
  • Connection & termination: 0.25" quick connects
Mode of Operation Series Input Voltage Time Ranges Time Adjustment Method Relay Output Form Options
Single Shot On Break TGPSL
  1. 120 VAC
  2. 230 VAC
  3. 24 VAC
  4. 24-28 VDC
  5. 48 VAC
  6. 48 VDC
  7. 12 VDC
  8. Any in between AC voltage (specify)
  9. Any in between DC voltage (specify>
  1. Variable, integral, knob on timer.
  2. Variable, external knob remote.
  3. Fixed, internal, factory set
  4. Fixed, external, resistor remote
  1. SPDT
  2. SPST
  3. SPST
  1. Heavy duty, 10 amps
0001 0.5 to 1 sec.
0001 0.5 to 1 sec.
0010 .1 to 10 sec.
0100 1 to 100 sec.
1000 10 to 1000 sec.
Any range up to 24 hours avaialble.
Specify time in full seconds or hours folowed by the letter "S" or "H" and the decimal amount of the main time unit.
Examples: 5S5 is 5.5 secs
5H5 is 5.5 hours