Power Cords From Rodale

Class
Insulation Class- description Standards SK
0

The "Class 0" appliances are without earthing protection and with a simple insulation, destinated to dry areas.

CEE 7- Sheet II 10-16A 250V SK
1

The "Class 1" appliances must have their chassis connected to the ground, by an earthconductor (yellow/green). The protection is assured by an automatic switch (generally a differential breaker) which, in case of defective insulation, cuts the electric power supply off, by discharging the current to the ground. The differential breaker must be set to the resistance of the earth-connection.

CEE7- Sheet IV 10-16A 250V

CEE7- Sheet VII 10-16A 250V

CEI 23-16/VII - 1971-1972 10A 250V, 16A 250V

AG/F- FM/F - BG/F

11GS/A - S17

ASE 1011
Sheet SNV 24507 10A 250V
CH/2
CENELEC
EN 60320
Sheet C 13 10A 250V
FR/C
CENELEC
EN 60320 Sheet C 15 10A 250V-
FR/W
2

The "Class II" appliances can be utilized in all areas without particular measures of protection. However, they must be manufactured under strict rules which assure the consumers that in the case of insulation defects no risk may occur.

CEE7 - Sheet XVI 2,5A, 250V

CEE7 - Sheet XVII 10-16A 250V

CEI 23-16/VII - 1971-72
10A 250V
16A 250V

SM - SR - RL

PF

10 GS/A - S16

ASE 1011
Sheet: SNV 24506 10A250V
CH/1

^Top of Page

Model Cord Section
SR
2,5A-250V
H03VH-Y 2x0,1
H03VH-H 2x0,50
2x0,75
H03VVH2-F 2x0,50
2x0,75
H05VVH2-F 2,x0,75
SM
2,5A-250V
H03VH-H 2x0,75
H03VVH2-F 2x0,75
H05VVH2-F 2x0,75
RL
2,5A-250V
H03VVH2-F 2x0,75
H05VVH2-F 2x0,75
H03VV-F 2x0,50
2x0,75
H05VVF 2x0,75
H05RR-F 2x0,75
H05RN-F 2x0,75
H03RT-F 2x0,75
Technical Features
Standards CEI 23-5
CEE 7 (XVI) Alternative II
Tables UNEL 4716768
DIN 49464 F
Two pole, no rewirable flat moulded on cord , without earth, used for Class II appliances; REVERSIBLE
Type 2P
Insulating Material thermoplastic, type PVC
Axial cord insulation type ordinary
Pins ø4.0mm nickelled brass. partly insulated
Rated Current 2.5A
Rated Voltage 250V

^Top of Page

Model Cord Section
10GS/A
10A-250V
H03VVH2-F 2x0,75
H05VVH2-F 2x0,75
H03VV-F 2x0,75
H05VV-F 2,x0,75
2,x1,0
H05RR-F 2,x0,75
2,x1,0
H05RN-F 2,x0,75
2,x1,0
H03RT-F 2,x0,75
2,x1,0
11 GS/A
10A-250V
H03VV-F 3x0,75
H05VV-F  3x0,75
3x1,0
H05RR-F  3x0,75
3x1,0
H05RN-F  3x0,75
3x1,0
H03RT-F  3x0,75
3x1,0
Technical Features
Standards CEI 23-16/VII-1971-1972
Tables UNEL 4716768
DIN 49464 F
Only for Italy
Twoi pole, non-rewritable flat plug,moulded on card, used for Class II appliances (ref type S10) or for the Class 1 appliances (ref type S11; REVERSIBLE)
Type 2P-S10 (without earth)
2P+E -S11 (with central earth pin)
Insulating Material thermoplastic, type PVC
Axial cord insulation type ordinary
Pins ø4.0mm nickelled brass, with phase pins partly insulated
Rated Current 10A
Rated Voltage 250V

^Top of Page

Model Cord Section
10GS/A
10A-250V
H03VVH2-F 2x0,75
H05VVH2-F 2x0,75
H03VV-F 2x0,75
H05VV-F 2x0,75
2x1,0
2x1,5
H05RR-F 2,x0,75
2,x1,0
2,x1,5
H05RN-F 2,x0,75
2,x1,0
H07RT-F 2,x1,0
H03RT-F 2x0,75
2x1,0
2x1,5
Technical Features
Standards CEI 23-5, CEE 7 (XVII)
Tables UNEL 47168-68
DIN 49406R
Two pole, non-rewirable plug, moulded on card, without earth, used for Class II appliances; REVERSIBLE
Type 2P
Insulating Material thermoplastic, type PVC
Axial cord insulation type Against water proofs
Pins ø4.8 nickelled brass
Rated Current 10A d.c./16A a.c.
Rated Voltage 250V d.c./a.c.

^Top of Page

Model Cord Section
AG/F
10/16A-250V
H03VV-F 3x0,75
H05VV-F 3x0,75
3x1,0
3x1,5
H005RR-F 3x0,75
3x1,0
H005RN-F 3x0,75
3x1,0
H005RT-F 3x0,75
3x1,0
FM/F H05VV-F 3x0,75
3x1,0
3x1,5
H05RR-F 3x0,75
3x1,0
H05RN-F 3x0,75
3x1,0
Technical Features
Standards CEI 23-5, CEE 7 (VII)
Tables UNEL 47166-68
DIN 49441 82
Two pole, non-rewirable plug with double earthing, moulded on card used for Class 1 appliances.
Type 2P + E + E
Insulating Material thermoplastic, type PVC
Angled cord insulation type Against water proofs
Pins ø4.8 nickelled brass
Rated Current 10A d.c./16A a.c.
Rated Voltage 250V d.c./a.c.

^Top of Page

Model Cord Section
S16
16A-250V
       
H03VV-F   2x0,75
2x1,0
2x1,5
H05RR-F  2x1,0
2x1,5
H05RN-F 2x1,0
H07RN-F  2x1,0
2x1,5
S17
16A-250V
       
H05VV-F   3x0,75
3x1,0
3x1,5
H05RR-F  3x1,0
3x1,5
H05RN-F 3x1,0
H07RN-F  3x1,0
3x1,5
Technical Features
Standards CEI 23-16/VII-1971 -1972
Only for Italy
Two pole, non-rewritable flat plug,moulded on card, used for Class II appliances (ref type S16) or for the Class 1 appliances (ref type S17; REVERSIBLE)
Type 2P - S16 (without earth)
2P + E -S17 (with central earth pin)
Insulating Material thermoplastic, type PVC
Axial cord insulation type ordinary
Pins ø5.0mm nickelled brass, with phase pins partly
Rated Current 16A
Rated Voltage 250V

^Top of Page

Model Cord Section
BG/F
10/16A-250V        
H03VV-F   3x0,75
H05VV-F   3x0,75
3x1,0
3x1,5
3x2,5
H05RR-F 3x0,75
3x1,0
3x1,5
H05RN-F 3x0,75
3x1,0
H07RN-F 3x1,0
3x1,5
H03RT-F 3x0,75
3x1,0
3x1,5
Technical Features
Standards CEI-23-5
CEE 7 (VII)
Tables UNEL 47166-68
DIN-49441 R2
Two pole, non-rewirable plug with double earthing, moulded on cord, used for Class 1 appliances
Type 2P + E + E
Insulating Material thermoplastic, type PVC
Axial cord insulation type against water proofs
Pins ø4.8mm nickelled brass
Rated Current 10A d.c/16A a.c.
Rated Voltage 250V d.c./a.c

^Top of Page

Model Cord Section
BG/F
10/16A-250V        
H03VV-F   3x0,75
H05VV-F   3x0,75
3x1,0
3x1,5
3x2,5
H05RR-F 3x0,75
3x1,0
3x1,5
H05RN-F 3x0,75
3x1,0
H07RN-F 3x1,0
3x1,5
H03RT-F 3x0,75
3x1,0
3x1,5
Technical Features
Standards ASE 1011
Tables Sheet SNV 24506- Type T11
Sheet SNV 24507- Type T12
Two pole, non-rewirable flat plug, moulded on cord, used for Class II appliances (ref sheet SNV 24506 - T11) or for class 1 appliances (ref Sheet 24507 - T12)
Type 2P - Sheet SNV 24506 - T11 (without earth) - Reversible
2P + E - Sheet SNV 24507 - T12 (with central earth pin) - non-reversible
Insulating Material thermoplastic, type PVC
Axial cord insulation type ordinary
Pins ø4.0mm nickelled brass
Rated Current 10A
Rated Voltage 250V

^Top of Page