Indoor Air Quality Data Logger ACR IAQ
|
 |
IAQ - Indoor Air Quality
The Indoor Air Quality logger combined with Telair 7001 monitor can record the three leading air indicators which are temperature, RH, and CO2.
|
temperature, RH, Carbon Dioxide
|
|
IAQ - Indoor Air Quality
|
|
Battery
|
3.6 volt Lithium, guaranteed for 10 years |
|
Logger Resolution
|
8 bits (1 part in 256) |
|
Number of Channels
|
- one intrenal temperature sensor
- one internal RH sensor
- one for CO2 sensor
- two for optional remote temp & RH sensor
|
|
Temperature Sensor Specification
|
|
|
RH Sensor Specification
|
-
capacitive thin polymer film
-
±4% from 10 to 90% (-20 to 40 °C [-4 to 104 °F])
-
better than 0.04% between 25 and 60% RH at 25 °C (77 °F)
|
|
CO2 Sensor Specification
|
-
response time: <60 seconds
-
accuracy: ±50 ppm or ±5% of reading, whichever is greater
-
warm up time: <60 seconds at 22 °C
|
|
PDF
|
|
|
|
| Size |
107 mm x 74 mm x 22 mm (4.2" x 2.9" x 0.9") |
 |
| Weight: |
110 grams (3.75 ounces) |
 |
| Case Material: |
NorylŪ Plastic |
 |
| Operating Limits: |
-40°C to 70°C (-40°F to 158°F) and 0 to 95% Relative Humidity (non-condensing) |
 |
| Clock Accuracy: |
+/-2 seconds per day |
 |
| Battery: |
3.6 volt Lithium, 1 Amp-Hour |
 |
| Power Consumption: |
5 to 10 microamps (continuous) |
 |
| Battery Life: |
10-years warrantied (under normal use) Factory replaceable |
 |
| Mounting: |
Magnetic backing or locking eyelet |
 |
| Memory Size: |
32 K (32,768 readings) |
 |
| Sampling Method: |
1. Continuous (First-in, First-out) 2. Stop when full (Fill-then-stop) |
 |
| Sampling Rate: |
User selectable rates between 8 seconds to once every 5 days |
 |
| Resolution: |
8 bits (1 part in 256) |
 |
| External Connector: |
Removable screw-type terminal strip with Common (-) connection |
 |
| PC Requirements: |
IBM PC or 100% compatible running MSŪ Windows 3.1, '95, '98, or NT, with at least 2 MB RAM, 2 MB of hard drive disk space and one free serial port |
 |
| Product Approvals: |
Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commision (FCC). Meets Class A radiated and conducted emission requirements of Section 2 of the Radio Interference Regulations of Communications Canada. IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emissions respectively, for the Commission of the European Communities (CE) |
 |
| Resistance to X-Rays: |
Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport X-Ray machine). Tested for protection against Gamma Ray (equivalent to 0.137 - 1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5" |
 |
|
Powerful Solutions for Instrumentation & Control Problems!
Indoor Air Quality Data Logger ACR IAQ
|