ACR JR-1001 Intrinsically Safe Logger
|
 |
JR-1001 Intrinsically Safe Logger
Use this Intrinsically Safe Logger in hazardous applications in which there are flammable gases or explosives.
|
Single Channel Temperature Data Logger
|
|
JR-1001 Intrinsically Safe
|
|
Sampling Interval
|
Adjustable, 8 seconds to 34 minutes |
|
Sampling Method
|
Continuous, Stop when Full |
|
Logger Resolution
|
0.4 °C @ 25 ° C (0.7 ° F @ 77 °F) |
|
Memory Size
|
32 KB or 32000 readings (up to 244800 readings when data compression selected) |
|
Temperature Sensor Specifications
|
-
Type: NTC Thermistor 10,000 ohms @ 25 °C (77 °F)
-
Range: -40 to 85 °C
(-40 to 185 °F)
-
Accuracy: ±0.2 @ 25 ° C
(±0.3 @ 77 °F)
|
|
Approval
|
UL Intrinsically Safe for use in:
- Class 1, Division 1, Groups A, B, C, D
- Class 2, Division 1, Groups E, F, G
- Class 3, Division 1, Hazardous Locations T3C
|
|
PDF
|
|
|
|
| Size |
33 x 43 x 20 mm (1.3" x 1.7" x 0.75") |
 |
| Weight |
35 grams (1.23 ounces)
|
 |
| Case Material |
Polyurethane |
 |
| Operating Limits |
-40 to 85 °C (-40 to 185 °F). 0 to 95% RH (non-condensing) |
 |
| Clock Accuracy |
+/-2 seconds per day |
 |
| Battery |
3 volt Lithium; 0.5 Amp-Hour |
 |
| Battery Life |
Five years warranty (under normal use) |
 |
| Memory Size |
32 KB (Up to 244800 data points when data compression is selected.)
|
 |
| PC Requirements |
IBM PC or 100% compatible running MS Windows 3.1, 95, 98, 2000, ME or NT, with a least 2 MB RAM, 2 MB of hard drive disk space and one free serial port. |
 |
| Approvals (common) |
Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commission (FCC). Meets radiated and conducted emmissions requirements of the Interference Causing Equipment Standard for Digital Apparatus of Industry Canada (ICES-003). IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emmissions respectively for the Commission of the European Communities (CE). |
 |
| Resistance to X-Rays |
Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport X-Ray machine). Tested for protection against Gamma Ray (equivalent to 0.137 - 1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5". |
 |
|
Powerful Solutions for Instrumentation & Control Problems!
ACR JR-1001 Intrinsically Safe Logger
|