Process Controls Home
 
 

ACR JR-1001 Intrinsically Safe Logger

JR-1001 Intrinsically Safe Logger

Use this Intrinsically Safe Logger in hazardous applications in which there are flammable gases or explosives.

Single Channel Temperature Data Logger
JR-1001 Intrinsically Safe 

Sampling Interval

Adjustable, 8 seconds to 34 minutes

Sampling Method

Continuous, Stop when Full

Logger Resolution

0.4 °C @ 25 ° C (0.7 ° F @ 77 °F)

Memory Size

32 KB or 32000 readings (up to 244800 readings when data compression selected)

Temperature Sensor Specifications

  • Type: NTC Thermistor 10,000 ohms @ 25 °C (77 °F)
  • Range: -40 to 85 °C
    (-40 to 185 °F)
  • Accuracy: ±0.2 @ 25 ° C
    (±0.3 @ 77 °F)

Approval

UL Intrinsically Safe for use in:
  • Class 1, Division 1, Groups A, B, C, D
  • Class 2, Division 1, Groups E, F, G
  • Class 3, Division 1, Hazardous Locations T3C

PDF

ACR,JR-1001,Intrinsically,Safe,Logger

Size 33 x 43 x 20 mm (1.3" x 1.7" x 0.75")
Weight

35 grams (1.23 ounces)

Case Material Polyurethane
Operating Limits -40 to 85 °C (-40 to 185 °F). 0 to 95% RH (non-condensing)
Clock Accuracy +/-2 seconds per day
Battery 3 volt Lithium; 0.5 Amp-Hour
Battery Life Five years warranty (under normal use)
Memory Size

32 KB (Up to 244800 data points when data compression is selected.)

PC Requirements IBM PC or 100% compatible running MS Windows 3.1, 95, 98, 2000, ME or NT, with a least 2 MB RAM, 2 MB of hard drive disk space and one free serial port.
Approvals (common) Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commission (FCC). Meets radiated and conducted emmissions requirements of the Interference Causing Equipment Standard for Digital Apparatus of Industry Canada (ICES-003). IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emmissions respectively for the Commission of the European Communities (CE).
Resistance to X-Rays Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport X-Ray machine). Tested for protection against Gamma Ray (equivalent to 0.137 - 1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5".


Powerful Solutions for Instrumentation & Control Problems!
ACR JR-1001 Intrinsically Safe Logger

Site Designed By Panther Marketing