AC Current Data Logger OWL 300
|
 |
OWL MODEL 300
The compact OWL model 300 records electric current in applications where typical recorders cannot fit. Due to its small size, the OWL model 300 can go directly into an electrical panel or even inside small electrical equipment allowing the user to record electric current in a safe, discreet and convenient manner.
|
Single Channel AC Current Data Logger
|
|
OWL MODEL 300
|
|
Frequency Range:
|
60 Hz - A60FL and A70FL current probes. 50 Hz - A65FL and A75FL current probes |
|
Current Ranges:
|
With OWL A60FL and A65FL: current probes: 5, 25, 100, 250 Amps. With OWL A70FL and A75FL: current probes: 10, 50, 250, and 500 Amps |
|
Accuracy:
|
+/-4% F.S. above 10% of range |
|
Memory Size:
|
32 KB |
|
PDF
|
|
|
|
| Size |
60 mm x 48 mm x 19 mm (2.4" x 1.9" x 0.7") |
 |
| Weight |
Watertight model (OWL 100); 80 g (2.8 oz.) Non-watertight model; 54 g (1.9 oz.) |
 |
| Case Material |
Watertight model (OWL 100 only);Polyurethane. Non-watertight model; NorylŪ Plastic |
 |
| Operating Limits |
-40°C to 70°C (-40°F to 158°F); 0 to 95% RH (non-condensing) on non-watertight models |
 |
| Clock Accuracy |
+/ - 2 seconds per day |
 |
| Battery |
3.6 volt Lithium, 10-years Warrantied (under normal use). Factory replaceable |
 |
| Memory Size |
32 K (32,767 readings) |
 |
| Sampling Method |
First-in, First-out, (First-in, First-out not available with sample rates faster than 8 seconds). Fill-then-stop, Delayed start, Trigger start |
 |
| Sampling Rate |
User selectable rates from 5 per second to once every 12 hours |
 |
| Resolution |
8 bit (1 part in 256). Can be optimized to the equivalent of 10 bit resolution |
 |
| Communication |
Optical Send/Receive from up to 1" between logger and interface cable (with no obstructions) |
 |
| Alarm Type |
Optical (Red LED) |
 |
| External Connector |
Removable snap type connector |
 |
| PC Requirements |
IBM PC or 100% compatible running MS Windows 3.1,95,98, or NT, with a least 2 MB RAM, 2 MB of hard drive disk space and one free serial port |
 |
| Product Approvals |
Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commission (FCC). Meets Class A radiated and conducted emission requirements of Section 2 of the Radio Interference Regulations of Communications Canada. IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emissions respectively for the Commission of the European Communities (CE) |
 |
| Resistance to X-Rays |
Tested for protection against a 160V dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times of an airport X-Ray machine). Tested for protection against Gamma Ray (equivalent to 0.137-1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5" |
 |
|
Powerful Solutions for Instrumentation & Control Problems!
AC Current Data Logger OWL 300
|