Process Controls Home
 
 

DC Current Data Logger OWL 500

OWL MODEL 500
The OWL model 500 is a rugged and versatile data logger that records DC current with ease and convenience. Ideal for monitoring (through commercially available transducers) a wide variety of measurement parameters. All current process signals can be converted into custom engineering units using TrendReader® Standard's simple equation editor.


Single Channel DC Current Data Logger
OWL MODEL 500 

Input Range:

0 to 24 mA max. DC

Accuracy:

+/-1% of full scale

Memory Size:

32 KB

No. of Channels:

One. (External DC Current)

Input Impedance:

100 ohms

PDF

DC,Current,Data,Logger,OWL,500

Size 60 mm x 48 mm x 19 mm (2.4" x 1.9" x 0.7")
Weight Watertight model (OWL 100); 80 g (2.8 oz.) Non-watertight model; 54 g (1.9 oz.)
Case Material Watertight model (OWL 100 only);Polyurethane. Non-watertight model; NorylŪ Plastic
Operating Limits -40°C to 70°C (-40°F to 158°F); 0 to 95% RH (non-condensing) on non-watertight models
Clock Accuracy +/ - 2 seconds per day
Battery 3.6 volt Lithium, 10-years Warrantied (under normal use). Factory replaceable
Memory Size 32 K (32,767 readings)
Sampling Method First-in, First-out, (First-in, First-out not available with sample rates faster than 8 seconds). Fill-then-stop, Delayed start, Trigger start
Sampling Rate User selectable rates from 5 per second to once every 12 hours
Resolution 8 bit (1 part in 256). Can be optimized to the equivalent of 10 bit resolution
Communication Optical Send/Receive from up to 1" between logger and interface cable (with no obstructions)
Alarm Type Optical (Red LED)
External Connector Removable snap type connector
PC Requirements IBM PC or 100% compatible running MS Windows 3.1,95,98, or NT, with a least 2 MB RAM, 2 MB of hard drive disk space and one free serial port
Product Approvals Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commission (FCC). Meets Class A radiated and conducted emission requirements of Section 2 of the Radio Interference Regulations of Communications Canada. IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emissions respectively for the Commission of the European Communities (CE)
Resistance to X-Rays Tested for protection against a 160V dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times of an airport X-Ray machine). Tested for protection against Gamma Ray (equivalent to 0.137-1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5"


Powerful Solutions for Instrumentation & Control Problems!
DC Current Data Logger OWL 500

Site Designed By Panther Marketing