SmartReader 1 Temperature Data Logger
|
 |
SmartReader 1
SmartReader 1 is an easy to use data logger for effortless temperature recording. Quick and easy to set up, it works right out of the box, logging temperature readings from its internal, precision-calibrated, on-board sensor. For added versatility, you can also use an optional remote temperature probe.
|
Two Channel Temperature Data Logger
|
|
SmartReader 1
|
|
Memory Size:
|
32 KB |
|
Accessories:
|
ACR ET Series Temperature Probe |
|
No. of Channels:
|
Two. (One for the internal temperature sensor and one for remote sensing of temperature, resistance, or switch status) |
|
Remote Network Communications:
|
See Network & Communications |
|
Common Specifications:
|
See Common Specs |
|
Industry:
|
Food, Storage Monitoring
|
|
PDF
|
|
|
|
|
Multi-channel, configurable data loggers
|
|
SmartReader
|
| Size |
107 mm x 74 mm x 22 mm (4.2" x 2.9" x 0.9") |
 |
| Weight: |
110 grams (3.75 ounces) |
 |
| Case Material: |
NorylŪ Plastic |
 |
| Operating Limits: |
-40°C to 70°C (-40°F to 158°F) and 0 to 95% Relative Humidity (non-condensing) |
 |
| Clock Accuracy: |
+/-2 seconds per day |
 |
| Battery: |
3.6 volt Lithium, 1 Amp-Hour |
 |
| Power Consumption: |
5 to 10 microamps (continuous) |
 |
| Battery Life: |
10-years warrantied (under normal use) Factory replaceable |
 |
| Mounting: |
Magnetic backing or locking eyelet |
 |
| Memory Size: |
32 K (32,768 readings) |
 |
| Sampling Method: |
1. Continuous (First-in, First-out) 2. Stop when full (Fill-then-stop) |
 |
| Sampling Rate: |
User selectable rates between 8 seconds to once every 5 days |
 |
| Resolution: |
8 bits (1 part in 256) |
 |
| External Connector: |
Removable screw-type terminal strip with Common (-) connection |
 |
| PC Requirements: |
IBM PC or 100% compatible running MSŪ Windows 3.1, '95, '98, or NT, with at least 2 MB RAM, 2 MB of hard drive disk space and one free serial port |
 |
| Product Approvals: |
Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commision (FCC). Meets Class A radiated and conducted emission requirements of Section 2 of the Radio Interference Regulations of Communications Canada. IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emissions respectively, for the Commission of the European Communities (CE) |
 |
| Resistance to X-Rays: |
Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport X-Ray machine). Tested for protection against Gamma Ray (equivalent to 0.137 - 1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5" |
 |
|
|