Process Controls Home
 
 

SmartReader 2 Data Logger

SmartReader 2
SmartReader 2 is a data logger for easy and reliable tracking of "air quality" conditions. It has a built-in temperature sensor and a plug-in Relative Humidity sensor. The Relative Humidity sensor is field replaceable so you can always be assured of accurate readings.


Four Channel RH and Temperature Data Logger
SmartReader 2 

Range:

0 to 95% (non-condensing)

Resolution:

Better than 0.4% between 25 & 60% RH at 25° C (77° F)

Accuracy:

+/-4% RH from 10 to 90% (-20° to 40°C [-4 to 104°F])

Memory Size:

32 KB

Accessories:

ACR EH-020A Temperature & RH Probe ACR ET Series Temperature Probe

No. of Channels:

Four. (One for the internal temperature sensor, one for the internal RH sensor, one for optional external RH and one for optional external temperature or resistance)

Relative Humidity Sensor:

Capacitive thin polymer film

Response Time:

Adequate ventilation reduces the response time which is approximately 5 minutes in still air

Environmental Conditions:

Like all relative humidity sensors, when exposed to contaminants and/or extreme environmental conditions, accuracy degradation could result. For maximum long-term stability, sensor should not be exposed or subjected to organic solvents, corrosive agents (strong acids, SO2, H2SO4, CI2, HCl, H2S, etc.), and strong bases (compounds with PH greater than 7). Dust settling on the sensor surface will not affect sensor performance except possibly to decrease the speed of response. For more information on the RH sensor’s tolerance to chemicals, see Accessories section under Relative Humidity

Remote Network Communications:

See Network & Communications

Common Specifications:

See Common Specs

Software:

See Software

Industry:

HVAC, Air Quality, Museums, AeroSpace

PDF

SmartReader 2 Data Logger

Size 107 mm x 74 mm x 22 mm (4.2" x 2.9" x 0.9")
Weight: 110 grams (3.75 ounces)
Case Material: Noryl® Plastic
Operating Limits: -40°C to 70°C (-40°F to 158°F) and 0 to 95% Relative Humidity (non-condensing)
Clock Accuracy: +/-2 seconds per day
Battery: 3.6 volt Lithium, 1 Amp-Hour
Power Consumption: 5 to 10 microamps (continuous)
Battery Life: 10-years warrantied (under normal use) Factory replaceable
Mounting: Magnetic backing or locking eyelet
Memory Size: 32 K (32,768 readings)
Sampling Method: 1. Continuous (First-in, First-out) 2. Stop when full (Fill-then-stop)
Sampling Rate: User selectable rates between 8 seconds to once every 5 days
Resolution: 8 bits (1 part in 256)
External Connector: Removable screw-type terminal strip with Common (-) connection
PC Requirements: IBM PC or 100% compatible running MS® Windows 3.1, '95, '98, or NT, with at least 2 MB RAM, 2 MB of hard drive disk space and one free serial port
Product Approvals: Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commision (FCC). Meets Class A radiated and conducted emission requirements of Section 2 of the Radio Interference Regulations of Communications Canada. IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emissions respectively, for the Commission of the European Communities (CE)
Resistance to X-Rays: Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport X-Ray machine). Tested for protection against Gamma Ray (equivalent to 0.137 - 1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5"