Process Controls Home
 
 

SmartReader 7 Process Signal Data Logger

SmartReader 7
SmartReader 7 is a versatile data logger for easy recording of common process signal variables. With seven input channels, the logger is ideal for monitoring (through commercially available transducers) a wide variety of measurement parameters.


Eight Channel Process Signal Data Logger
SmartReader 7 

Standard Input Ranges:

0 to 2.5 volts DC. 0 to 5.0 volts DC (two channels). 0 to 10.0 volts DC. 0 to 200 millivolts DC. 0 to 25 milliamps DC (two channels)

Optional Input Ranges:

All external channels 0 to 2.5 volts, 0 to 5 volts, 0 to 10 volts, or 0 to 25mA

Accuracy:

+/-1% full scale

Memory Size:

32 KB

No. of Channels:

Eight. (One internal for ambient temperature and seven external for analog voltage and current loop signals)

Input Impedance:

Greater than 1 M ohm (200 mV channel). Greater than 1 M ohm (0 to 2.5 V channel). 20 K ohms (0 to 5.0 V channels). 40.9 K ohms (0 to 10.0 V channel). 100 ohms (0 to 25 mA channels)

Transducer Restrictions:

The use of a single power supply is recommended to avoid ground loops or use loop isolators

Voltage Channels:

+/-40 volts
(reverse-polarity protected)

Current channels:

+/- 70 mA
(reverse-polarity protected)

Remote Network Communications:

See Network & Communications

Industry:

Process Control, Process Signals, Commercial, Industrial, Production Characteristics Monitoring

PDF

SmartReader,7,Process,Signal,Data,Logger

Size 107 mm x 74 mm x 22 mm (4.2" x 2.9" x 0.9")
Weight: 110 grams (3.75 ounces)
Case Material: NorylŪ Plastic
Operating Limits: -40°C to 70°C (-40°F to 158°F) and 0 to 95% Relative Humidity (non-condensing)
Clock Accuracy: +/-2 seconds per day
Battery: 3.6 volt Lithium, 1 Amp-Hour
Power Consumption: 5 to 10 microamps (continuous)
Battery Life: 10-years warrantied (under normal use) Factory replaceable
Mounting: Magnetic backing or locking eyelet
Memory Size: 32 K (32,768 readings)
Sampling Method: 1. Continuous (First-in, First-out) 2. Stop when full (Fill-then-stop)
Sampling Rate: User selectable rates between 8 seconds to once every 5 days
Resolution: 8 bits (1 part in 256)
External Connector: Removable screw-type terminal strip with Common (-) connection
PC Requirements: IBM PC or 100% compatible running MSŪ Windows 3.1, '95, '98, or NT, with at least 2 MB RAM, 2 MB of hard drive disk space and one free serial port
Product Approvals: Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commision (FCC). Meets Class A radiated and conducted emission requirements of Section 2 of the Radio Interference Regulations of Communications Canada. IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emissions respectively, for the Commission of the European Communities (CE)
Resistance to X-Rays: Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport X-Ray machine). Tested for protection against Gamma Ray (equivalent to 0.137 - 1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5"


Powerful Solutions for Instrumentation & Control Problems!
SmartReader 7 Process Signal Data Logger