Process Controls Home
 
 

SmartReader 9 Pulse Data Logger

SmartReader 9
SmartReader 9 is a versatile data logger designed for easy counting and recording of switch contact closures and voltage pulses. It has two input channels each with three selectable frequency ranges.


Three Channel Pulse Data Logger
SmartReader 9 

Range:

32 Pulses/second; 64 Pulses/second; 128 Pulses/second

Memory Size:

32 KB

No. of Channels:

Three. (One internal thermistor and two external inputs for externally-generated pulse signals or dry switch contact closures)

Input Impedance:

750 K ohms

Minimum Pulse Width:

4 milliseconds

Switch Contact Closure Input (Input Type):

Uncommitted switch or relay contacts

Logic Type:

Active logic signals

Input Voltage:

Low= 0 to 0.5 volts (DC). High= 4.5 to 24 volts (DC)

Remote Network Communications:

See Network & Communications

Industry:

Pulse Counting, Pulse Monitoring, Machinery Auditing, Atmospheric Monitoring, Switch Counts

PDF

SmartReader,9,Pulse,Data,Logger

Size 107 mm x 74 mm x 22 mm (4.2" x 2.9" x 0.9")
Weight: 110 grams (3.75 ounces)
Case Material: NorylŪ Plastic
Operating Limits: -40°C to 70°C (-40°F to 158°F) and 0 to 95% Relative Humidity (non-condensing)
Clock Accuracy: +/-2 seconds per day
Battery: 3.6 volt Lithium, 1 Amp-Hour
Power Consumption: 5 to 10 microamps (continuous)
Battery Life: 10-years warrantied (under normal use) Factory replaceable
Mounting: Magnetic backing or locking eyelet
Memory Size: 32 K (32,768 readings)
Sampling Method: 1. Continuous (First-in, First-out) 2. Stop when full (Fill-then-stop)
Sampling Rate: User selectable rates between 8 seconds to once every 5 days
Resolution: 8 bits (1 part in 256)
External Connector: Removable screw-type terminal strip with Common (-) connection
PC Requirements: IBM PC or 100% compatible running MSŪ Windows 3.1, '95, '98, or NT, with at least 2 MB RAM, 2 MB of hard drive disk space and one free serial port
Product Approvals: Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commision (FCC). Meets Class A radiated and conducted emission requirements of Section 2 of the Radio Interference Regulations of Communications Canada. IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emissions respectively, for the Commission of the European Communities (CE)
Resistance to X-Rays: Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport X-Ray machine). Tested for protection against Gamma Ray (equivalent to 0.137 - 1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5"


Powerful Solutions for Instrumentation & Control Problems!
SmartReader 9 Pulse Data Logger

Site Designed By Panther Marketing