SmartReader Plus 10
SmartReader Plus 10 is a four channel, RTD data logger designed to precisely measure temperature over a wider temperature range than a thermistor without sacrificing accuracy or resolution.


Four Channel Temperature Data Logger
SmartReader Plus 10 

Accuracy:

+/- 0.06% of temperature span

Memory Size:

128 KB

Accessories:

None

No. of Channels:

Four. (One internal thermistor temperature channel and three external RTD channels)

RTD Type:

Any 100 or 1000 ohm Platinum RTD with a Temperature Coefficient of Resistance (TCR) of 0.00385

Temperature Range:

For 100 and 1000 Ohm Probes only: -230 to 300° C (-382 F to 572° F)

Wiring Configurations:

2, 3, or 4 wire RTDs

Remote Network Communications:

See Network & Communications

Industry:

Industrial, Commerical

PDF

SmartReader,Plus,10,Four,Channel,RTD,Data,Logger

Size 107 mm x 74 mm x 22 mm (4.2" x 2.9" x 0.9")
Weight: 110 grams (3.75 ounces)
Case Material: NorylŪ Plastic
Operating Limits: -40°C to 70°C (-40°F to 158°F) and 0 to 95% Relative Humidity (non-condensing)
Clock Accuracy: +/-2 seconds per day
Battery: 3.6 volt Lithium, 1 Amp-Hour
Power Consumption: 5 to 10 microamps (continuous)
Battery Life: 10-years warrantied (under normal use) Factory replaceable
Mounting: Magnetic backing or locking eyelet
Memory Size: 32 K (32,768 readings)
Sampling Method: 1. Continuous (First-in, First-out) 2. Stop when full (Fill-then-stop)
Sampling Rate: User selectable rates between 8 seconds to once every 5 days
Resolution: 8 bits (1 part in 256)
External Connector: Removable screw-type terminal strip with Common (-) connection
PC Requirements: IBM PC or 100% compatible running MSŪ Windows 3.1, '95, '98, or NT, with at least 2 MB RAM, 2 MB of hard drive disk space and one free serial port
Product Approvals: Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commision (FCC). Meets Class A radiated and conducted emission requirements of Section 2 of the Radio Interference Regulations of Communications Canada. IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emissions respectively, for the Commission of the European Communities (CE)
Resistance to X-Rays: Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport X-Ray machine). Tested for protection against Gamma Ray (equivalent to 0.137 - 1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5"