SmartReader Plus 3 easily and accurately records AC current and voltage. The easy-to-use ACR CT's provide safe current readings by simply clamping them around the power leads. AC voltage is monitored by connecting ACR's AC voltage transducer to the 5V channels.


Eight Channel AC Current & Voltage Data Logger
SmartReader Plus 3 

Current Ranges:

With A60FL (60 Hz) and A65FL (50 Hz): 5,25,100 and 250 Amps.With A70FL (60 Hz) and A75FL (50 Hz) current probes: 10, 50, 250 and 500 Amps. Up to 3000 Amps with the ACR CT-50-2

Nominal Voltage Ranges:

120 V (1 phase, 60 HZ). 480 V (3 phase, 60 HZ)

Memory Size:

32, 128 KB and 1.5 MB

No. of Channels:

Eight. (One internal for ambient temperature, four for AC current for use with ACR probes and three with 0-5 VDC inputs, which can be used with ACR AC voltage transducers to monitor 3 phase voltage

Remote Network Communications:

See Network & Communications

Industry:

Electrical, Power Quality, Power Monitoring

PDF

SmartReader,Plus,3,AC,Current,Voltage,Data,Logger

Size: 107 x 74 x 22 mm (4.2" x 2.9" x 0.9")
Weight: 110 grams (3.75 ounces)
Case Material: NorylŪ Plastic
Operating Limits: -40°C to 70°C (-40°F to 158°F) and 0 to 95% Relative Humidity (non-condensing)
Clock Accuracy: +/-2 seconds per day
Battery: 3.6 volt Lithium, 1 Amp-Hour
Power Consumption: 5 to 10 microamps (continuous)
Battery Life: 10-years warrantied (under normal use). Factory replaceable
Memory Size: 32 K (21,500 readings). 128 K (87,000 readings). 1.5 MB (1,000,000 readings). See specific models for availability
Sampling Method: 1. Continuous (First-in, First-out); not available with sample rates faster than 8 seconds.) 2. Stop when full (Fill-then-stop)
Sampling Rate: User selectable rates from 25 per second to one reading every 8 hours. (BP-101 battery pack or PS-201 Power Supply required for sample rates faster than 8 seconds. See Accessories section for details)
Resolution: 12 bit (1 part in 4096)
PC Requirements: IBM PC or 100% compatible running MSŪ Windows 3.1,95,98, or NT, with a least 2 MB RAM, 2 MB of hard drive disk space and one free serial port
Product Approvals: Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commission (FCC). Meets Class A radiated and conducted emission requirements of Section 2 of the Radio Interference Regulations of Communications Canada. IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/ Burst and Radiated Emissions respectively for the Commission of the European Communities (CE)
Resistance to X-Rays: Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport X-Ray machine). Tested for protection against Gamma Ray (equivalent to 0.137-1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5"