Application:
This compact, powerful luminaire can be used for integral light/sight port (single flange version) or separate light and sight ports (dual flange version) to illuminate the internals of visual flow indicators, pipelines, laboratory mixers and other vessels and reactors which are normally closed. This model is intended for use in all Non Hazardous Areas. The unit is suitable for food processing. The luminaire must never be inserted into a vessel wall as a sealing element, i.e. without appropriate Sight Glass disc and fitting.
Sight Glass Styles:
This powerful, compact size luminaire is designed to give glare free illumination in combination with Sight Glass styles as the following:
-
bolted circular flanges Model DIN 28120 or similar styles
-
circular screwed flanges Series MV DN 100 and larger
-
visual flow indicators (tubular or flat glass)
Size:
The luminaire is mostly suitable for Sight Glasses DN 50 and larger.
Protection:
Dust and waterjet proof to IP 65 and EN 60529.
Ambient Condition Operating Range:
This unit is suitable for ambient temperatures of 80°C at the cable gland. It is independent of internal vessel pressure or vacuum. When ambient temperature exceeds 40°C, consult factory when ordering. Temperature resistant cable is necessary.
Power supply:
The unit can be fitted with various halogen lamps, and thus is suited for AC or DC voltage.
Lamp sockets:
see table on following page
Transformers:
Transformers with 12V or 24 V secondary voltage are optionally available
Additions:
- DN 50 to DN 125 for light ports only
- DN 125 to DN 200 for single flange light/sight ports
-
special claw spanner: for opening/tightening the lens ring
-
installed automatic delay switch Lumiglas Timer, 5 minutes of operation time
|