Rotronic HygroFlex Models
|
 |
Models | Probes| Metal Enclosure Option| Software| Calibration
The HygroFlex is available in three standard versions which share the following features:
Interchangeable probes
Fully user programmable
Software based probe calibration and instrument configuration
Optional display and keypad
• Test connector for HygroPalm calibrator
12...35 VDC / 12...24 VAC or 90...264 VAC power
 |
HygroFlex 1 : Analog Outputs
%RH and temperature
Two linear analog outputs: 4-20 mA, 0-5V, etc.
Jumper configuration of analog outputs signal type
Analog outputs can be configured for practically any
range
One probe input |
 |
HygroFlex 2 : Digital Output
%RH and temperature
Calculated values; dew-point, mixing ratio, etc
RS232 output (%RH and temperature)
Networkable
(RS232 first HygroFlex to PC / RS485 between
transmitters)
Optional 2nd probe input
(digital or analog e.g. pressure) |
 |
HygroFlex 3: Analog & Digital Outputs
%RH, temperature and calculated value
(dew-point, mixing ratio, etc)
Three linear analog outputs: 4-20 mA, 0-5V, etc.
Jumper configuration of analog outputs signal type
Analog outputs can be configured for practically any
range
RS232 output (%RH and temperature)
Networkable
(RS232 first HygroFlex to PC / RS485 between
transmitters)
Optional 2nd probe input
(digital or analog e.g. pressure) |
Maximum network cable length: RS232: 12m (39ft) / RS485: 1,000m (3,300ft) between the two furthermost units.
|
Powerful Solutions for Instrumentation & Control Problems!
Rotronic Hygroflex Models
|
|