Rotronic M2 Series Temperature and Humidity Transmitter

Rotronic,M2,Series,Temperature,Humidity,Transmitter

  • Fully interchangeable HygroClip probe eliminates maintenance downtime
  • Proven sensor technology provides ± 1.5% RH/± 0.3°C
    (± 0.5°F) accuracy
    (click here for details)
  • Probe operating limits: 0...100%RH and
    -40...85°C/-40...185°F
  • Long term stability of better than 1% RH per year
  • Potentiometer free - digital calibration
  • On-site loop validation and calibration with HygroPalm 3 calibrator
  • Duct, wall and remote probe configurations
    (remote probe can be separated from transmitter by up to 5 m / 16.4 ft)
  • 2-wire loop-powered or 3-wire versions
  • Optional display (3-wire version only)
  • Unique, cost effective installation procedure

M2 Series Specifications

PROBE M22 M23
Probe type
HygroClip S
Humidity sensor
Rotronic C94 thin film capacitive
Temperature sensor
Pt100 RTD
Operating limits
0...100%RH
-40...85°C / -40...185°F
Repeatability
better than 0.5%RH and 0.1°C/°F
Humidity sensor stability
better than 1% RH per year
Sensor protection
type D15G, stainless steel wire mesh, PPS frame
Probe material
Polycarbonate
TRANSMITTER
M22
M23
Circuit type
2-wire loop-powered
3-wire
Signal type
4...20 mA
0...20 mA, 4...20 mA
0...1V, 0...5V, 0...10V
(user selectable)
Measuring range
0...100% RH
0...100°F (other ranges are available)
System accuracy at 23°C
± 1.5% RH / ± 0.3°C (± 0.5°F)
Operating limits
0...99% RH non condensing
-40...60°C (-40...140°F)
-30...60°C (-22...140°F) with optional display
Power supply
10...35 VDC, 10 + 0.02 x load
2 x 20 mA
12...35 VDC (65 mA) or 12...24 VAC
Maximum load for current outputs
250 Ohm
Minimum load for voltage outputs
n/a
1000 Ohm
User configurable output signals
n/a
output scale and temperature unit configurable with the HW3 software

output signal type (current or voltage) configurable with solder pads
Display option
No
Yes
LC, 2 line numeric
1 line alphanumeric
1/4 character height, resolution 0.1
Electrical connections
Cable grip and terminals
Housing material
ABS
Protection grade
IP65/NEMA4
Housing dimensions w/o probe
154 x 72.5 x 48 mm (6.06 x 2.86 x 1.89")
Weight
300 g / 0.7 lb

Back To Top

M2 Series Electrical Diagrams


M23    3-wire
Current outputs Voltage outputs
M22    2-wire loop-powered

Note: 1 and 3 (+) are connected
Base Plate (all models)

Model Terminal
M23 1 + 10..35VDC / 24VAC
2  - Ground (common)
3 + Temperature
4 +  Humidity
Model Terminal
M22 1/3 + 10..35VDC
2  - Temperature
4  - Humidity

Back To Top

M2 Series Accessories

MOK-XX-DAT05 Extension cable for M22 / M23  wall mount (remote probe)
XX= 02 (2m / 6ft) or 05 (5m / 15ft)

HygroPalm 3 HygroPalm 3,  field calibrator
ACRLXB5 Cable: service connector M22 / M23  to HygroPalm 3 for field calibration (probe connected to transmitter) and loop validation.

ACML232 Configuration cable for the M23 only, connects the service connector to the COM port of a PC. Both the scale of the M23 output signals and the temperature unit can be changed when the HW3 software is installed on the PC.

MOK-02-WIN Calibration cable for the HygroClip S probe (when the probe is removed from the transmitter) - supplied with 9-pin COM port adapter

HW3 Calibration / configuration software on CD ROM
HygroClip Sxx/yy HygroClip S probe simulator where xx = relative humidity in %RH and yy = temperature in °C (fixed values)
HygroClip R Fully calibrated, refurbished HygroClip S
(HygroClip Exchange Program)
ER-15 Calibration device for HygroClip
EAXX-SCS Certified humidity standards (5 per box)
XX = 00. 05, 10, 20, 35, 50, 65, 80, 95%RH
Back To Top

M2 Series Installation:
   
Modular design simplifies installation and facilitates maintenance

Each M2 series transmitter consists of a base plate and a measurement module (electronics). The transmitters are calibrated at our factory and are shipped in an individual box for protection during shipment or storage.

Installation is a simple 2-step process:

Mount b.jpg (9027 bytes)

Step 1

The base plate is mounted and wired (a standard electrical box may be used in the case of a wall installation). Since the measurement module is not required during this part of the installation, it can be safely stored until all the work is completed.

Mount a.jpg (9327 bytes)

Step 2

Upon completion of the wiring work, the module is just snapped into the base plate and secured with the screws provided. Any module can be installed with any base plate, no special matching is required.

When it is time to re-certify calibration or if a repair is required, simplyreplace the HygroClip probe or the electronics module. Rehabilitated, fully calibrated and certified replacement probes and modules are available from RIC.

HygroClip Plug-in Probe

Both the HygroClip S and the base of the connector on the transmitter are marked with a dot. The locking ring is marked with 2 dots.

 

The probe can be inserted straight into the connector when all dots are aligned. When the dots are not aligned, the probe should be rotated clockwise during insertion.

After inserting the probe, turn the locking ring clockwise to secure the probe.

Back To Top


Field Service made easy



Service cable ACRLXB5

 

Each M2 series transmitter features a service connector that can be accessed without disturbing the output signals.

Service cableACRLXB5 is used to connect the service connector of the M2 to probe input 2 of the HygroPalm 3 portable indicator.

Field Calibration

Using the HygroPalm 3 indicator and the ACRLXB5 service cable, the following can be done:

a) 1-point adjustment of the HygroClip S probe against a reference probe connected to the HygroPalm

b) single- or multi-point adjustment against a reference environment (requires a humidity generator). When no humidity generator is available, ROTRONIC offers easy-to-use certified humidity standards to generate known humidity values

It is also possible to calibrate the HygroClip probe while removed from the transmitter. This allows a periodic rotation of the probes.

See: Probe Calibration

Validation of the signal loop

By displaying the signals of the M2 transmitter with the HygroPalm 3, the entire measuring loop can be validated: probe, transmitter, wiring and central processing unit. If so desired, the HygroClip probe can be replaced with a certified probe simulator that generates known fixed humidity and temperature values.

Back To Top