Rotronic M3 Series Temperature and Humidity Transmitter

Rotronic,M3,Series,Temperature,Humidity,Transmitter

  • Fully interchangeable HygroClip probe eliminates maintenance downtime
  • Proven sensor technology provides ± 1.5% RH / ± 0.3°C (± 0.5°F) accuracy
    (click here for details)
  • Probe operating limits: 0...100%RH and -40...85°C/-40...185°F
  • Long term stability of better than 1% RH per year
  • Potentiometer free - digital calibration
  • On-site loop validation and calibration with HygroPalm 3 calibrator
  • Duct, wall and remote probe configurations
    (remote probe can be separated from transmitter by up to 5 m / 16.4 ft)
  • Networkable through RS485 port
  • Optional display
  • Unique, cost effective installation procedure

M3 Series Specifications

PROBE
Probe type
HygroClip S
Humidity sensor
Rotronic C94 thin film capacitive
Temperature sensor
Pt100 RTD
Operating limits
0...100%RH
-40...85°C / -40...185°F
Repeatability
better than 0.5%RH and 0.1°C/°F
Humidity sensor stability
better than 1% RH per year
Sensor protection
type D15G, stainless steel wire mesh, PPS frame
Probe material
Polycarbonate
TRANSMITTER
Circuit type
3-wire
Signal type
0...20 mA, 4...20 mA, 0...1V, 0...5V, 0...10V
(user selectable)
Analog outputs

Two analog outputs corresponding to any combination of the following:
relativehumidity, temperature, computed parameter (dew point, etc.)
or user defined calculation

Digital output / Networking
RS485 - up to 31 M3 transmitters on one network connected as slaves to one HygroFlex 2 or 3 master. RS232 connection from master to PC.
Computed parameter
dew point, wet bulb, enthalpy, vapor concentration, specific humidity, mixing ratio, vapor concentration at saturation, partial pressure of water vapor, saturation pressure of water vapor, or a user defined calculation such as the difference between temperature and dew point
Measuring range
0...100% RH, 0...100°F
other ranges are available for humidity, temperature
and the computed parameter
System accuracy at 23°C
± 1.5% RH / ± 0.3°C (± 0.5°F)
Operating limits
0...99% RH non condensing
-40...60°C (-40...140°F)
-30...60°C (-22...140°F) with optional display
Power supply
12...35 VDC (65 mA) or 12...24 VAC
Maximum load for current outputs
250 Ohm
Minimum load for voltage outputs
1000 Ohm
User configurable analog outputs
scale and unit of each analog output configurable with the HW3 software

output signal type (current or voltage) configurable with solder pads
Display option
LC, 2 line numeric
1 line alphanumeric
1/4 character height, resolution 0.1
Electrical connections
Cable grip and terminals
Housing material
ABS
Protection grade
IP65/NEMA4
Housing dimensions w/o probe
154 x 72.5 x 48 mm (6.06 x 2.86 x 1.89")
Weight
300 g / 0.7 lb

Back To Top

M3 Series Electrical Diagrams


M3    3-wire
Current outputs Voltage outputs

Base Plate

1 + 10..35VDC / 24VAC
2 - Ground (common)
3  + Temperature
4 +  Humidity
5 +  RS485
6 -   RS485

Back To Top

M3 Series Accessories

MOK-XX-DAT05 Extension cable for M3  wall mount (remote probe)
XX= 02 (2m / 6ft) or 05 (5m / 15ft)

HygroPalm 3 HygroPalm 3,  field calibrator
ACRLXB5 Cable: service connector M3 to HygroPalm 3 for field calibration (probe connected to transmitter) and loop validation.

ACML232 Configuration cable for the M3, connects the service connector to the COM port of a PC. The parameter corresponding to each output signal as well as the scale and unit can be changed when the HW3 software is installed on the PC.

MOK-02-WIN Calibration cable for the HygroClip S probe (when the probe is removed from the transmitter) - supplied with 9-pin COM port adapter

HW3 Calibration / configuration software on CD ROM
HygroClip Sxx/yy HygroClip S probe simulator where xx = relative humidity in %RH and yy = temperature in °C (fixed values)
HygroClip R Fully calibrated, refurbished HygroClip S
(HygroClip Exchange Program)
ER-15 Calibration device for HygroClip
EAXX-SCS Certified humidity standards (5 per box)
XX = 00. 05, 10, 20, 35, 50, 65, 80, 95%RH
Back To Top

M3 Series Installation:
   
Modular design simplifies installation and facilitates maintenance

Each M3 series transmitter consists of a base plate and a measurement module (electronics). The transmitters are calibrated at our factory and are shipped in an individual box for protection during shipment or storage.

Installation is a simple 2-step process:

Mount b.jpg (9027 bytes)

Step 1

The base plate is mounted and wired (a standard electrical box may be used in the case of a wall installation). Since the measurement module is not required during this part of the installation, it can be safely stored until all the work is completed.

Mount a.jpg (9327 bytes)

Step 2

Upon completion of the wiring work, the module is just snapped into the base plate and secured with the screws provided. Any module can be installed with any base plate, no special matching is required.

When it is time to re-certify calibration or if a repair is required, simplyreplace the HygroClip probe or the electronics module. Rehabilitated, fully calibrated and certified replacement probes and modules are available from RIC.

HygroClip Plug-in Probe

Both the HygroClip S and the base of the connector on the transmitter are marked with a dot. The locking ring is marked with 2 dots.

 

The probe can be inserted straight into the connector when all dots are aligned. When the dots are not aligned, the probe should be rotated clockwise during insertion.

After inserting the probe, turn the locking ring clockwise to secure the probe.

Back To Top


Field Service made easy



Service cable ACRLXB5

 

Each M3 series transmitter features a service connector that can be accessed without disturbing the output signals.

Service cableACRLXB5 is used to connect the service connector of the M3 to probe input 2 of the HygroPalm 3 portable indicator.

Field Calibration

Using the HygroPalm 3 indicator and the ACRLXB5 service cable, the following can be done:

a) 1-point adjustment of the HygroClip S probe against a reference probe connected to the HygroPalm

b) single- or multi-point adjustment against a reference environment (requires a humidity generator). When no humidity generator is available, ROTRONIC offers easy-to-use certified humidity standards to generate known humidity values

It is also possible to calibrate the HygroClip probe while removed from the transmitter. This allows a periodic rotation of the probes.

See: Probe Calibration

Validation of the signal loop

By displaying the signals of the M3 transmitter with the HygroPalm 3, the entire measuring loop can be validated: probe, transmitter, wiring and central processing unit. If so desired, the HygroClip probe can be replaced with a certified probe simulator that generates known fixed humidity and temperature values.


Networking   

Networking via a RS232/485 network provides an excellent alternative to using the M3 transmitter analog output signals: simpler wiring, reliable digital communication and added functionality such as data logging, alarm functions, etc.  Using a HygroFlex transmitter as the master (RS232/RS485 interface), up to 31 M3 transmitters can be connected to form a network. Either the Rotronic HW3 software or a custom made R232 communications software can be used on a PC to read the network.

COM port
RS232 up to 12 m (39ft)
3 wires
RS485 up to 1000 m (3300 ft) between the two furthermost units 2 wires