Coin Counting Timers - MC Series Timers
Coin Counting Timers - MC Series Timers
|
|
 |
MC Series Coin Counter
The MC series Coin Counting Timers combine a single shot
timing mode and coin counting capability with microprocessor technology for reliability and accuracy.
Two 4-position binary switches allow users to select the number of coins as well as the time period.
The switches can accommodate from 1 to 15 coins and accurately set time periods from .5 to 7.5 minutes
with excellent repeatability. The units have an option of an accumulation function, a last coin alarm
or an output to a coin counter.
When required, the unit can be supplied with a fixed factory-set coin count or time period.
The MC series coin counters come complete with a relay capable of switching loads up to 20
amps,1.5HP. The electronic components are encapsulated in a 2.5" square package for protection
from the elements.
|
Timing Mode
Input voltage is applied continuously.
After the correct amount of coins has been counted by the timer, the relay will
energize for the selected time period. This unit will automatically reset, after
the selected time period expires and is ready for another cycle.
|
 |
|
FEATURES |
-
Coin mechanism debouncer
-
Coin jam sensor
-
Counts 1-15 coins (fixed or adjustable with dip switch)
-
Counts .5 -7.5 minutes
( fixed or adjustable with dip switch)
-
High current carrying capacity - up to 20 amps, 1.5 HP
-
100% Load isolation
- No leakage in N.O. position
|
-
No heat sinking required
-
Totally encapsulated for protection from harsh environments
-
Transient protected
-
No minimum load required
- 100% Operational testing before shipping
|
| BASIC WIRING AND DIMENSIONS |
 |
| SPECIFICATIONS |
Input Voltages: VDC: 12 to 24
VAC: 12,24,120,230,50/60 Hz
Time Delay:
- Timing Mode: Single Shot on Make
- Type: Digital CMOS - Programmable
- Time Range: 5-7.5 minutes (standard)
Others on request
Repeatability: ±0.1%
Setting Accuracy: ±0.1% typical(fixed or variable)
Reset Time: 100 milliseconds
|
Relay Life Expectancy:
- Mechanical: Up to 10 million operations
- Electrical: 100,000 operations at max. load
Protection:
- Polarity Protection: All DC units have reverse polarity protection
- Transient Protection: 18 joules
- Dielectric Strength: 1800V RMS 60 Hz
Temperature Ranges:
- Storage: -40°C to +85°C
- Operating: -40°C to +85°C
Coin Counter: Up to 15 (standard)
Others on request |
| SELECTION PROCEDURE
|
| Series |
Input Voltage |
5 Digit Program Number
(established at the factory to customer's application) |
Number of Outputs |
| MC |
1 120 VAC
2 230 VAC
3 24 VAC
4 24 VDC
7 12 VDC
8 VAC (Specify)
Example: 8(32) 32 VAC
9 VDC (Specify)
Example: 9(30) 30 VDC
|
Example #1
00019= Standard Unit
Example #2
00022= Standard Unit with output to coin counter
|
First Digit= # of 6 or 10 amps Current Outputs
Maximum of 2
Second Digit= Relay Suffix
(X=6 amps, H=10 amps)
Third Digit= # of 20 amps Outputs
Maximum of 1
Fourth Digit= Relay Suffix
(J=20 amps, 1.5 HP)
|
|
|