Dual,Seal,Failure,Detector,Model,4092,Time,Mark

  Products

Dual Seal Failure Detector Model 4092 from Time Mark

Description
The Model 4092 Dual Seal Failure Detector is designed specifically for monitoring the shaft seals of two submersible pumps.

The probes are installed in the seal cavities of each of the pumps. When a seal begins to leak, contaminating fluid enters the seal cavity, lowering the resistance between the probe and the common connection. If the resistance drops below the sensitivity set-point, the corresponding relay and the LED indicator are activated. The Model 4092 Dual Seal Failure Detector will automatically reset when the fault condition is corrected. The sensitivity is field adjustable.


Hot Features:

  • 120VAC and 240VAC versions
  • Adjustable sensitivity
  • Automatic reset
  • 5-Year unconditional warranty

Applications for Dual Seal Failure Detector Model 4092

Dimensions for