ClearView, Flow Meter, Lake MonitorsFor media compatibility, select from:

ClearView, Flow Meter, Lake Monitors

Polycarbonate body (ClearView H20) or

ClearView, Flow Meter, Lake Monitors

Polysulphone body (ClearView+)

  • UNRESTRICTED MOUNTING
    Allows for horizontal, vertical or inverted installation of the meter.

  • COMPACT AND RUGGED DESIGN
    Measures less than 8-1/4" long and 2-7/16" diameter with a rigid tube and union nut design.

  • VISUAL INSPECTION OF FLUID
    The transparent body allows for visual inspection of fluid conditions. Diagnose problems at a glance.

  • MULTIPLE MATERIALS AND CALIBRATIONS AVAILABLE
    With a variety of wetted materials of construction and media calibrations, the ClearView™ will be well suited to your process.

  • SENSING METHOD ASSURES ACCURACY
    The proven variable-area piston metering assembly provides accurate, dependable flow rate indication.

  • SUPERIOR READABILITY
    High contrast scale/indicator provides easy-to-read flow rate measuring resolution along with dual units of GPM and LPM.

  • MULTIPLE PORTING OPTIONS
    ClearView end ports are available in a variety of materials, sizes, and threading options, to simplify installation.

  • LOW COST PRECISION
    Measuring accuracy of ±5% of range and repeatability of ±1%.


ENGINEERING SPECIFICATION

The Basic Series Liquid Flow Rate Meter Shall:

  • Use the variable area piston metering method to measure flow rate.

  • Not require inlet or outlet straight plumbing, or require vertical pipe mounting.

  • Have a measuring accuracy of ±5% of full scale with ±1% repeatability.

  • Be Lake Monitors No. CV - _ _ - _ _

Materials of Construction (Wetted Components)
ClearView H2O
ClearView +

Brass

Brass

 

Polysulphone

Polysulphone

Seals

Buna-N

Buna-N

Spring

Stainless Steel

Stainless Steel

Body

Polycarbonate

Polysulphone

Indicator

Polysulphone

Polysulphone


Performance

Measuring accuracy:

±5% of full-scale

Repeatability:

±1% of full-scale

Flow measuring range:

1– 30 GPM (5-110 LPM)

Turn Down Ratio (All Ranges):

10:1

Maximum operating pressure:

325 PSIG (22.4 Bar)

Maximum operating temperature:

ClearView H2O 200°F (93°C) ClearView+ 250°F (121°C)

Filtration requirements:

74 Micron (200 U.S. mesh) minimum


Mechanical Size Code
Clear View CAD

DIM

1/2" Female NPTF

3/4" Female NPTF

1" Female NPTF

A

2-7/16" (62mm)

2-7/16" (62mm)

2-7/16" (62mm)

B

7-9/16" (192mm)

7-9/16" (192mm)

7-5/32" (182mm)

Port Type

NPTF, BSPP

NPTF, BSPP

NPTF, BSPP


Download Brochure