Phosphate Ester Flow Rate Monitors
|
|
|
|
Three Materials of Construction:
Select from aluminum, brass or stainless steel construction to meet system requirements.
|
|
|
Rugged and Reliable:
These monitors are constructed with all metal pressure vessels, allowing safe, permanent, installation in industrial systems.
|
|
|
Unrestricted Mounting:
Allows the designer to install the monitor in any orientation; horizontal, vertical or inverted.
|
|
|
|
High Pressure Operation:
The magnetically coupled follower allows operation to 6000 PSIG.
|
|
|
Twenty-Three Different Ports Available:
Standard selection of NPT, SAE and BSP ports permits system design versatility.
|
|
|
Multi-Use:
Factory calibrated for phosphate ester. These versatile monitors can be used to verify hydraulic power unit outputs and to test machinery and tools for proper fluid flow rates.
|
|
|
Low Cost Precision:
Mid-scale measuring accuracy: within ±2.5%. Full-scale accuracy: within ±4%.
|
|
|
ENGINEERING SPECIFICATIONS:
The Phosphate Ester in-line flow rate monitor shall:
|
|
be factory calibrated for phosphate ester measurements.
|
|
|
use the variable annular orifice technique with compression spring recovery.
|
|
|
not require inlet or outlet stright plumbing, or require vertical pipe mounting.
|
|
|
have a measuring accuracy of ±2.5% of full scale in the center third of the measuring range, and ±4% of full scale accuracy over the entire flow measuring range.
|
|
|
have a stainless steel sharp-edged orifice.
|
|
|
be Lake Monitors No. P _ _ - _ _ _ - _ _.
|
|
|
MATERIALS OF CONSTRUCTION:
Wetted Components
|
Component
|
Aluminum
|
Brass
|
Stainless Steel
|
|
High-pressure casing, end ports and tapered shaft
|
Aluminum
|
Brass
|
#304 Stainless Steel
|
|
Seals
|
EPR
|
EPR
|
EPR
|
|
Transfer Magnet
|
Teflon® coated Alnico
|
Teflon® coated Alnico
|
Teflon® coated Alnico
|
|
Floating Orifice Disk
|
Stainless Steel
|
Stainless Steel
|
Stainless Steel
|
|
All other internal parts
|
Stainless Steel
|
Stainless Steel
|
Stainless Steel
|
|
MATERIALS OF CONSTRUCTION:
Non-Wetted Components
|
Component
|
Aluminum
|
Brass
|
Stainless Steel
|
|
Window Tube
|
Pyrex
|
Pyrex
|
Pyrex
|
|
Window Seals
|
Teflon®
|
Teflon®
|
Teflon®
|
Teflon, Viton and Kalrez are registered trademarks of duPont de Nemours & Co.
|
PERFORMANCE:
|
|
Measuring Accuracy:
±2.5% of
full-scale in the center third of the measuring range; ±4% of full-scale over the entire scale range.
|
|
|
Repeatability:
±1% of full scale
|
|
|
Pressure Differential:
less than 30 PSIG
|
|
|
Maximum Operating Temperature:
240ºF (116ºC) Note: for operation to 600ºF (316ºC) alternate o-ring material will be required.
|
|
|
Maximum Operating Pressure:
Aluminum and Brass monitors: 3500 PSIG (240 Bar) Stainless Steel monitors: 6000 PSIG (410 Bar)
|
|
|
Flow Range1:
0.1-130 GPM (0.4-490 LPM)
|
|
|
Standard Calibration Fluids:
DTE 25 @ 110ºF, 0.873 sg. Monitors are density corrected to 1.16 sg.
|
1 To determine approximate measuring ranges multiply the range listed in the Liquid Flow Rate section of Lake's Guide to standard monitor numbers by 0.93. For example, a P3A6WB10 would have a scale range to 10 GPM * 0.93 = 9.3 GPM at full scale.
|
|
MECHANICAL:
|
|
|
|
|
DIM
|
Series 3
|
Series 4
|
Series 5
|
Series 5
|
|
A
|
1-7/8"
(48mm)
|
2-3/8"
(60mm)
|
3-1/2"
(90mm)
|
3-1/2"
(90mm)
|
|
B
|
6-9/16"
(167mm)
|
7-5/32"
(182mm)
|
10-1/8"
(258mm)
|
12-5/8"
(322mm)
|
|
Port Sizes
|
NPTF:1/4",3/8",1/2"
SAE:#6,#8,#10
BSP:3/8",1/2"
|
NPTF:3/4",1"
SAE:#12,#16
BSP:3/4",1"
|
NPTF:1-1/4",1-1/2"
SAE:#20
BSP:1-1/4"
|
NPTF:2"
SAE:#32
BSP:2"
|
|
|
PRESSURE DIFFERENTIAL VS FLOW RATE:
|
|
|