Low Cost Stroboscope
DT-721
(AC-Powered)
DT-725
(Battery Powered)
40.0 - 12,500 RPM/FPM
and higher using harmonics
The CHECK-LINE® DT-721 and DT-725 Digital Stroboscopes are highly stable, industrial-quality instruments for non-contact RPM measurement as well as for inspection and observation of moving parts by freezing or slowing down the action.
A Kit option is offered for both models which also includes a carrying case and spare flash tube at minimal additional cost.
|
|
Features
AC or battery-powered models
Highly accurate speed control with drift-free operation
Easy-to-use controls with bright LED display
Instant double (2x) and half-rate (÷2) flash selection
Accepts input from sensor for external flash triggering
Phase shift adjustment permits movement of objects to desired position for convenient observation
Extremely lightweight and rugged
External
Trigger Operation >>>
Suitable for applications requiring external control of the flash rate using a sensor or other input device. An external power source may be required.
|
|
Complete Kit
| Optional Complete Kit is offered for both models which also includes a carrying case and spare flash tube at minimal additional cost.
|
 |
Dimensions
Specifications
| Flash Range |
40.0 - 12,500 FPM |
Phase Shift |
0 - 359° (Internal Mode) |
| Accuracy |
± 0.02% of reading |
Operating Time |
1 hour (Model 725 only) |
| Resolution |
(0.1) 40.0 - 4,999.9 |
Charging Time |
15 hours |
| |
(0.2) 5,000.0 - 7,999.8 |
Low Battery Indicator |
Model 725 only |
| |
(0.5) 8,000.0 - 9,999.5 |
Operating Temperature |
32 to 105° F (0 to 40° C) |
| |
(1.0) 10,000.0 - 12,500.0 |
Weight |
|
| Display |
5-Digit LED, 8 mm high |
Model 721 |
1.50 lbs. (680 g) |
| Flash Tube |
Xenon, 10 watt |
Model 725 |
2.75 lbs. (1.25 Kg) |
| Tube Life |
100 million flashes |
Power Requirements |
|
| Flash Duration |
10 - 15 µs |
Model 721 |
115 VAC ± 10%, 50/60 Hz |
| Signal Output |
NPN Open Collector, 24 VDC max.
at 50 mA (150 µs typical) |
Model 725 |
Internal battery
(Lead Acid Rechargeable) |
| External Trigger Input Signal |
a) 12 - 24 V DC through a 3-wire NPN sensor (requires external power supply)
b) 12 V DC through a 2-wire proximity sensor (Leakage Current 1 mA max. Load current 8 mA min.)
c) Switch or Relay Contact |
|