 Series 1090 Loop Alarms™ Acccepts inputs from Thermocouples, RTD's or Voltage

Loop Alarms™ Accept inputs from thermocouples (1290), RTDs (1490) or process devices (1090). SPDT relay outputs can be set for latching or non-latching, direct or reverse action and high or low function. Output behavior is easily programmable via switches. Mount in standard 11-pin sockets.

Dimensions: Including socket pins,
2 3/8"W x 3 7/16"H x 1 ¾"D
(60.3 mm W x 87.3mm H x 44.4 mm D

PHYSICAL DATA

Isolation: 1500 Volts RMS between input, outputs and power
Power Supply: 85-265 VDC/VAC, 50-400 Hz
Setpoint: Adjustable form 0-100% of span
Deadband: Adjustable from 0.25-100% of span
Drift: ±0.02% per °C typical, ±0.05% per °C maximum
Ambient Operating Temperature: 32 to 131°F (0 to 55°C) non-condensing
Input Impedance: (1290) 3 megohms, (1090) Voltage input=1 megohms, Current input=10 ohms Search Current (1490): Cu 10Ω = 5 mA. Pit 100Ω, Ni100Ω, Ni120Ω=500mA. Pit 500Ω, NiFe 1000Ω, NiFe 2000Ω=100mA. Pit 100Ω=50mA.
Relay Output: SPDT, one set per setpoint, 5A @ 250 VAC resistive
Latch Circuit Reset: Automatic at power up. Manual with reset switch
Lead Compensation Error (1490): 0.02%/Ω
Indicators: One dual color LED per setpoint; red=On, green=Off
Open Thermocouple Protection (1290): Selectable upscale or downscale

Model 1290 Input Type and Ranges
Type E Thermocouple
-454 to +302°F (-270 to +150°C)
-454 to +554°F (-270 to +290°C)
32 to +302°F (0 to +150°C)
32 to +554°F (0 to +290°C)
32 to +1220°F (0 to +660°C)
32 to +1832°F (0 to +1000°C)

Type S Thermocouple
32 to +1922°F (0 to +1050°C)
32 to +3200°F (0 to +1760°C)

Type T Thermocouple -454 to +410°F
(-270 to +210°C)
-454 to +734°F (-270 to +390°C)
32 to +440°F (0 to +210°C)
32 to +734°F (0 to +390°C)
Type J Thermocouple
-346 to +374°F (-210 to +190°C)
-346 to +680°F (-210 to +360°C)
32 to +374°F (0 to +190°C)
32 to +680°F (0 to +360°C)
32 to +1400°F (0 to +760°C)

Type K Thermocouple
-454 to +482°F (-270 to +250°C)
-454 to +896°F (-270 to +480°C)
32 to +482°F (0 to +250°C)
32 to +896°F (0 to +480°C)
32 to +2501°F (0 to +1372°C)

Type R Thermocouple
32 to +1778°F (0 to +970°C)
32 to +3200°F (0 to +1760°C)
Model 1490 Input Type and Ranges
Pt 100, 500, 1000 RTDs
32 to 212°F (0 to 100°C)
32 to 572°F (0 to 300°C)
32 to 932°F (0 to 500°C)
Ni100 RTDs
-58 to +302°F (-50 to +150°C)
Ni120 RTDs
-58 to +482°F (0 to +250°C)
Cu10 RTDs
32 to 482°F (0 to 250°C)
NiFe 1000, 2000 RTDs
-58 to +392°F (-50 to +200°C)
Model 1090 Input Type and Ranges
Voltage Inputs
0 to 10mV     0 to 500mV
0 to 50mV     0 to 1V
0 to 100mV     0 to 5V
0 to 200mV     0 to 10V
Current Inputs
O to 1mA     0 to 20mA
0 to 5mA     0 to 50mA
0 to 10mA     0 to 100mA