double and reinforced insulation between contact sets according to EN 50 178
- Clearance and creepage distances > 5,5 mm
- dielectric strength > 8 kV at contamination 2
clearance and creepage distances, coil and contact > 8 mm
low rated power consumption
high mechanical service life
compact size, small height
Approvals: TÜV, UL, CSA
Applications: Press control ZH1/457
Switchgear for safety technology
high switching reliability due to crown contacts with large relative movement
compact size
Approvals: TÜV, UL, CSA
Applications: Press control ZH1/457
Escalators and walkways EN 115 / 12.98
Elevators DIN EN 81 Part 1 / 05.2000, TRA 101 / 07.80
Switchgear for safety technology
Safety relay, monostable OA 5601, OA 5602, OA 5603
acc. to EN 50 205, IEC 255, IEC 664 VDE 0106
with positively driven contacts
contact opening > 0,5 mm for the whole life, as well as with malfunction and with 1,6 UN>
Clearance and creepage distances, coil and contact ³ 8 mm
high voltage resistance > 4 kV
high switching reliability due to crown contacts
small height 39,5 mm
wide temperature range:
at OA 5601 and 5602: - 25 ... + 85 °C
at OA 5603: - 25 ... + 75 °C
high continous thermal current Ith = 10 A
mechanical service life
high voltage range 0,7 UN ... 1,6 UN
double and reinforced insulation between contact sets according to EN 50 178
Approvals: TÜV, UL, CSA
Applications: Press control ZH1/457
Escalators and walkways EN 115 / 12.98
Elevators DIN EN 81 Part 1 / 05.2000, TRA 101 / 07.80
Switchgear for safety technology