PowerWatch 120V is the easiest way to monitor and record essential voltage disturbance information from any North American power receptacle. Just set up your pre-determined disturbance threshold values or use the industry standard default values and plug it in. No wiring or dangerous connections required.
Specifications
| |
Hot to Neutral |
Neutral to Ground |
| Surge, Sag & Outage |
|
Range
|
0 to 200 V rms |
3 to 200 V rms |
|
Accuracy
|
+/- 1 V rms + resolution |
+/- 1 V rms + resolution |
|
Resolution
|
1 V rms |
1 V rms |
| Impulse |
|
Range
|
100 to 2500 V peak |
50 to 2500 V peak |
|
Accuracy
|
+/- 10% of reading + resolution |
+/- 10% of reading + resolution |
|
Resolution
|
10 V |
10 V |
|
Width Detection
|
1 µsec minimum |
1 µsec minimum |
|
Phase Angle Accuracy
|
+/- 1° (20 to 180°, 200 to 360°) |
+/- 1° (20 to 180°, 200 to 360°) |
|
Phase Angle Resolution
|
1° |
1° |
| Frequency |
|
Range
|
45 to 65 Hz |
|
Accuracy
|
+/- 0.1 Hz (3 cycles minimum) |
|
Resolution
|
0.1 Hz |
| Time Events (< 1 sec) |
|
Accuracy
|
+/- 0.5 cycle |
+/- 1 cycle |
|
Resolution
|
0.5 cycle |
1 cycle |
| Time Stamp (> 1 sec) |
|
Accuracy
|
+/- 2 seconds/day + resolution |
|
Resolution
|
8 seconds |
Ordering Information
| Model |
Compatibility |
Catalog # |
| PWV-001 |
North America |
01-0066 |