BSB,BOD,Sensomat,System,AL,336/342

BSB/BOD Sensomat System
AL 336/342


BSB/BOD Sensomat System AL 336/342

  • measurements from up to 100 different measurements points can be accessed simply by push-button with infra-red remote operation
  • duration of measurement can be selected between 30 minutes ... 99 days: e.g., BSB 5 , BSB 7 , BSBn or short-term BOD measurements
  • a really user-friendly means of BOD measurement
  • graphic presentation of BOD curves with mean value display
  • software-supported evaluation of series of measurements with statistical functions
  • electronic storage ensures extra security for measurements and other data
  • complies with GLP-/ISO 9000

The BSB/BOD-Sensomat-System comprises three interlocking, non-contact modules:

  • the pressureSENSOR-IR acts simultaneously as the measurement device and the storage unit for the measured results. Together with the sample vessel, it forms a mobile, self-contained measuring unit.
  • theBSB/BOD-Sensomat is the transportable §core" of the system: it logs all measured data at the push of a button and ensures simple, comprehensive evalutation and documentation of results.
  • theInductive Stirring System ensures the gas-exchange between the water sample and the air phase by periodic monitoring of the centering of the magnetic agitation rod.

Measuring principle:

Respirometric; mercury-free; electronic pressure sensor

Measuring ranges [mg/l O2]:

0 - 40, 0 - 80, 0 - 200, 0 - 400, 0 - 800, 0 - 2000, 0 – 4000 mg/l

Applications:

BOD5, BOD7, OECD 301 F ...

Result display:

BOD [mg/l]; 4 digit; 7-segment LED

Measuring parameter display:

BOD, volume, duration, measuring time

Measuring duration:

Selectable, between 1 and 28 days

Automatic result memory:

Up to 28 results, depending on measuring duration

Storage interval:

Hourly to daily, depending on measuring duration

Autostart:

on/off switching facility, measure-ment begins after pressure drops, or maximum waiting period

Current result:

Can be called up at any time

Power supply:

3 alkaline manganese ”C” (Baby) batteries

Battery life: 1 year based on normal use as BOD5 measuring unit (max. one reading daily); early warning at end of battery life

Clock:

Real-time clock

Protection class (sensor head):

IP54

Housing:

ABS

Approval certificate:

CE

Measuring Systems

Cat.-No.

Item

418336

BSB/BOD-Sensomat-System AL 336
for 6 measuring places, complete with BSB/BOD-Sensomat, Sensor-IR, Inductive Stirring System AL 311 and standard accessories, 230V/50-60 Hz

418347

BSB/BOD-Sensomat-System AL 336
for 6 measuring places, complete with BSB/BOD-Sensomat, Sensor-IR, Inductive Stirring System AL 311 and standard accessories, 115V/50-60 Hz

418342

BSB/BOD-Sensomat-System AL 342
for 12 measuring places, complete with BSB/BOD-Sensomat, Sensor-IR, Inductive Stirring System AL 322 and standard accessories, 230V/50-60 Hz

418348

BSB/BOD-Sensomat-System AL 342
for 12 measuring places, complete with BSB/BOD-Sensomat, Sensor-IR, Inductive Stirring System AL 322 and standard accessories, 115V/50-60


BSB/BOD Sensomat System
AL 336/342


Site Designed And Maintained By Panther Marketing And Design