BOD-OxiDirect,BOD,Measurement,System

BOD-OxiDirect
BOD Measurement System


BOD-OxiDirect – BOD Measurement System

  • Direct display of BOD values in mg/l
  • User-friendly handling
  • User-selectable measuring period
  • Result memory for up to 28 days (BOD5, BOD7, OECD...)
  • Measuring ranges from 0-40 mg/l to 0-4000 mg/l BOD
  • Accurate measurements
  • Autostart function following temperature equalisation of the samples
  • Environment-friendly
    as mercury-free
  • Automatic stirrer rod centering by the inductive stirrer system
The new AQUALYTIC® BOD-OxiDirect sensor system permits exact and convenient measurement of the Biochemical Oxygen Demand (BOD) based on the respirometric principle. All results are shown in a big display directly in mg/l BOD without the need for time-consuming conversion using factors. In addition, the measuring period can be user-selected between 1 and 28 days.

The unit measures BOD levels via the pressure drop in the closed system during a defined period of time. Following measurement, the results are stored and can be called up to the display at any time. The inductive stirrer system not only mixes the sample but also ensures optimum gas exchange between sample and gas space in the sample flask.

Alongside the BOD unit to determine BOD levels, a BOD system contains sample flasks, a non-wearing inductive stirrer system, overflow measuring flask to measure the sample volume, nitrification inhibitor and potassium hydroxide as an absorbent.

Measuring principle:

Respirometric; mercury-free; electronic pressure sensor

Measuring ranges [mg/l O2]:

0 - 40, 0 - 80, 0 - 200, 0 - 400, 0 - 800, 0 - 2000, 0 – 4000 mg/l

Applications:

BOD5, BOD7, OECD 301 F ...

Result display:

BOD [mg/l]; 4 digit; 7-segment LED

Measuring parameter display:

BOD, volume, duration, measuring time

Measuring duration:

Selectable, between 1 and 28 days

Automatic result memory:

Up to 28 results, depending on measuring duration

Storage interval:

Hourly to daily, depending on measuring duration

Autostart:

on/off switching facility, measure-ment begins after pressure drops, or maximum waiting period

Current result:

Can be called up at any time

Power supply:

3 alkaline manganese ”C” (Baby) batteries

Battery life: 1 year based on normal use as BOD5 measuring unit (max. one reading daily); early warning at end of battery life

Clock:

Real-time clock

Protection class (sensor head):

IP54

Housing:

ABS

Approval certificate:

CE


BOD-OxiDirect
BOD Measurement System


Site Designed And Maintained By Panther Marketing And Design