Low Flow Meter
Operating Principle:
The Kenco 1618 Low Flow Meter is part of an oil supply system for a stationary engine or compressor crankcase. The 1618 is installed on the inlet side of the crankcase, upstream of a Kenco Oil Level Controller. The 1618 Low Flow Meter will provide a constant, accurate measurement of oil consumption by the crankcase, the power cylinder lubricators, and the compressor cylinder lubricators. A single pole single throw reed switch is also available as an option; the switch will close momentarily every time the piston inside the meter strokes.
The Kenco 1618 is the low maintenance, cost-effective solution for visible and accurate readings of engine oil consumption.
Features:
-
Double action, single piston meter
-
Measures flow rates up to 5 gallons per hour
-
Provides an Indication of Engine Condition
-
Registers up to 9,999 gallons
-
Counter Immersed in Oil, Assuring Maximum Resistance to Wear From Vibration
-
SPST reed switch available(Model 14308)
Specifications:
MODEL 1618
MATERIALS OF CONSTRUCTION:
Housing - Aluminum
Seal Material - Buna-N
Chamber Seal Material - Teflon
Register Mechanism - Zinc Based Lusteron K Coated Lithographed Numbers
PROCESS CONNECTION:
Oil Inlet - 1/2" FNPT
Oil Outlet - 1/4" FNPT
DESIGN DATA:
Single Cycle Displacement - 1/50th Gallon
Single Stroke Displacement - 1/100th Gallon
Maximum Working Pressure - 50 psi
Maximum Flow - 5 Gallons per Hour
Accuracy - Factory Tested +/- 0.75%
* For Gravity Flow, Recommended Static Head Pressure Is 12 Feet Above the Oil Controller.
** IMPORTANT: When a 1618 meter is installed upstream from a KENCO oil level controller, the inlet pressure on the oil level controller will be reduced by one half.
MODEL 14308
MATERIAL OF CONSTRUCTION:
Housing - Aluminum
Seal Material - Buna-N
Chamber Seal Material - Teflon
Register Mechanism - Zinc Based Lusteron K Coated Lithographed Numbers
PROCESS CONNECTIONS:
Oil Inlet - 1/2" FNPT
Oil Outlet - 1/4" FNPT
Conduit Connection - 1/2" MNPT
SWITCH DATA:
Circuitry - Single Pole Single Throw
Switch Closure Rate - 50 Closures per Gallon
Maximum voltage - 100 Volts DC
Maximum Current - 0.25 Amps DC
Maximum Power - 7.0 Watts
DESIGN DATA:
Single Cycle Displacement - 1/50th Gallon
Single Stroke Displacement - 1/100th Gallon
Maximum Working Pressure - 50 psi
Maximum Flow - 5 Gallons per Hour
Accuracy - Factory Tested +/- 0.75%
* For Gravity Flow, Recommended Static Head Pressure Is 12 Feet Above the Oil Controller.
** IMPORTANT: When a 14308 meter is installed upstream from a KENCO oil level controller, the inlet pressure on the oil level controller will be reduced by one half.
|