Valves,Liquid Level Gauges,KTV Tubular Valves

Valves For Liquid Level Gauges - KTV Tubular Valves




Valves For Liquid Level Gauges - KTV Tubular Valves

APPLICATION:

The KENCO Tubular Valve (KTV), when used with a KENCO "SAFEGUARD" level gauge or KENCO "EPG" level gauge, provides maximum operator safety and environmental protection from a potential gauge glass failure. The KTV is designed for service in low to medium pressure applications up to 500 psig.

FEATURES:

  • The 1/8" thick o-ring provides for easy installation of the glass and requires less wrenching of the packing nut to seal
  • Positive O-ring seal gauge glass connection
  • 1/2" OR 3/4" MNPT rigid vessel connections
  • Ball check shut off
  • Inline vent and drain connection for easy glass cleaning
  • Straight pattern design
  • Braided PTFE stem packing
  • Flanged vessel connections available
  • All valves are supplied with 316 S.S. valve stems, ball checks and glass packing washer
  • The bodies are precision cast investment castings with each body pressure tested to assure quality
SPECIFICATIONS



TRANSMITTER ELECTRICAL DATA:
POWER SUPPLY = 12 - 30Vdc ± 10%; 24Vdc nominal
SUPPLY VOLTAGE EFFECT = Less than 0.01% of span/volt change
AMBIENT TEMPERATURE RANGE = -40°F to 176°F or -40°C to 80°C
HUMIDITY = 100% Condensing
ACCURACY = ±0.1% of span
REPEATABILITY = ±0.05% of span
LINEARITY (SOLID PROBE) = ±0.1% of span
LINEARITY (FLEXIBLE PROBE) = 0.025% of span
RESOLUTION = 0.01mA
RESPONSE TIME = 300 msec
TEMPERATURE EFFECT = ±0.01% of span/°F or 0.018% of span/°C
ERROR INDICATION = 3.6mA, 22mA, or Hold last value; field selectable
RANGE = 15-100,000pF
DAMPING = 0-60 seaconds; field adjustable in 1 sec. increments
MAXIMUM REMOTE DISTANCE = 10 feet between the electronics and the probe
OPERATOR INTERFACE:
Data Entry = 3-button key pad; magnetic touch
Display = 2 line by 8-character LCD
OUTPUT:
Analog = 4-20mA; 3.8-20.5mA overtravel; reversible
Digital = HART® communications protocol

SAFETY APPROVALS: FM APPROVED
Explosion Proof = Division 1; Class I: Groups B,C,D; Class II; Groups E,F,G; Class III
Intrinsically Safe = Division 1; Class I: Groups A,B,C,D; Class II; Groups E,F,G; Class III
Non-Incendive = Division 2; Class I: Groups A,B,C,D; Class II; Groups F,G; Class III



Valves For Liquid Level Gauges - KTV Tubular Valves