KOBOLD Model DWU, DWS and DWP
Paddle/Bellows Flow Meter a
nd Switch
es are based on the paddle, or static plate, principle. This type of arrangement is ideal for use in applications where dirt and solid grain contaminants are of concern. The paddle-bellows arrangement offers large internal clearances and mechanical insensitivity to a wide range of particulate matter.
Paddle/Bellows
Flow Meter and Switches
Operation
The simplicity of the DW
Paddle/Bellows
Flow Meter and Switch
es
design is its major asset. The devices operate as follows:
The flow causes the paddle, or
static plate to be deflected in the direction of flow against
the force of a spring. A bellows, made of bronze (or preferably
stainless steel), hermetically isolates the medium from the measuring/indicating
section. The motion of the paddle is transmitted directly to a
mechanical indicator and switch, or to a signal conditioner in
the case of analog output versions.
The DW series of
Paddle/Bellows
Flow Meter and Switch
es
comes in a variety of mounting styles. Units are available mounted
in a pipe TEE for in-line installation into pipes to 2-1/2"
with either threaded or flanged ends. For larger pipe applications,
the DW is available in a weld-on design usable on pipes with diameters
up to 24 inches.
Paddle/Bellows
Flow Meter and Switches
Analog Output Option
For installations requiring remote indication of flow, we offer the DW series of Paddle/Bellows Flow Meter and Switch
es
with optional analog output (option »-AN«). The meter continues to function in the standard way, except that rather than a mechanical dial movement, an inductive motion transducer is input to a signal conditioning circuit which provides a 4-20 mA flowrate signal and LCD display.
The analog output option allows
for remote transmission of system flowrate. A three digit LCD
display with 0.4" tall characters is standard with all analog
output versions making quick flow rate readings a snap.
Switching capability is not part
of the standard configuration with option -AN analog output meters.
If switching capability is desired in addition to the analog output,
2 external relays can be provided as part of the transmitter electronics.
Paddle/Bellows
Flow Meter and Switch
es
Special Features:
-
Accuracy: ± 3% Full Scale
-
Paddle Bellows Design Excellent
for Highly Contaminated Media
-
Orientation Independent
-
Brass or Stainless Steel
-
High Current Switching Capability
-
Insensitive to Magnetic Fields
Paddle/Bellows Flow Meter and Switches Product Specifications:
|
|
|
0
to 6 GPM:
|
± 5% of full scale
|
|
6
to 60 GPM:
|
± 4% of full scale
|
|
Over
60 GPM:
|
± 3% of full scale
|
|
Flow
Media:
|
Liquids
|
|
Flow
Range:
|
0.65 to 18 ft/sec
|
|
|
|
|
|
Max/Min Ratio
|
Paddle/Bellows Flow Meter and Switches
Additional Product Info
Click here to download a PDF file for this product.
Paddle/Bellows Flow Meter and Switches Product Manual
Click here
to download a manual for this product in PDF format.
|