Non-Metallic AODD Pump
Capacity: Adjustable 0 to 95 GPM
Max/Min Air Pressure:
LKT 70/20 PSI
Other Models 100/20 PSI
Dry Lift Capacity at MAX PSI:
Models w/ Teflon Balls 10 ft.
Other Models 15 ft. Models (Wetted Materials) Max Temp
LPB-1 1/2" (PP/BUNA N) 150°F
LPT-1 1/2" (PP/TEFLON) 150°F
LKT-1 1/2" (PVDF/TEFLON) 200°F
Applications:
Filter press, tank cleaning systems, pigments and resins, etc. Features:
- Absolutely lube-free and non stalling operation
- Can safely run dry
- Self-priming dry or wet
- Centre block made of corrosion-free plastic
- Few, easily accessible construction parts
- Flow rate up to 492 l/min
Benefit:
- No risk of pump failure due to to poor lubrication
- No contaminating of the environment or of the product itself by oil vapour
- Gentle pumping of liquids and pastes
- Flow rate and pressure can be regulated continuously
- No dynamic seals
- Possible air leakage arising at connections or in case of diaphragm rupture does not harm the air system
- Easy maintenance without special tools
|
|
Metallic AODD Pump
Capacity: Adjustable 0 to 95 GPM
Max/Min Air Pressure:
LKT 70/20 PSI
Other Models 100/20 PSI
Dry Lift Capacity at MAX PSI:
Models w/ Teflon Balls 10 ft.
Other Models 15 ft.
Models (Wetted Materials) Max Temp
LAB-1 1/2" (ALUMINUM/BUNA N) 180°F
LAT-1 1/2" (ALUMINUM/TEFLON) 200°F
LSB-1 1/2" (STAINLESS/BUNA N) 180°F
LST-1 1/2" (STAINLESS/TEFLON) 200°F
Applications:
Filter press, tank cleaning systems, pigments and resins, etc.
Features:
- Absolutely lube-free and non stalling operation
- Can safely run dry
- Self-priming dry or wet
- Centre block made of corrosion-free plastic
- Few, easily accessible construction parts
- Flow rate up to 492 l/min
- Explosion-proof version in compliance with ATEX
- Directive 94/9/EC, category 2
Benefit:
- No risk of pump failure due to to poor lubrication
- No contaminating of the environment or of the product itself by oil vapour
- Gentle pumping of liquids and pastes
- Flow rate and pressure can be regulated continuously
- No dynamic seals
- Possible air leakage arising at connections or in case of diaphragm rupture does not harm the air system
- Easy maintenance without special tools
|