Portable,pH,Conductivity,TDS,DS,pDS,Meters

Portable pH, Conductivity, TDS & DS, pDS Meters


Portable pH, Conductivity TDS, DS, pDS Meters

Applications

Boilers

Cooling Towers

Deionization
Reverse Osmosis
Chemical Concentrations
Printing Fountain Solutions
Plating & Parts Washing
Swimming Pools
Water Pollution Control

For Readings 
You Can Rely On


Model EP-11/pH
Our most popular pDS model features four conductivity ranges and a 2-12 pH range

No water supply is completely pure.  Every industrial, commercial or natural source contains dissolved solids or salts. These impurities contribute to scale, corrosion, poor taste, and environmental pollution that endanger animal and plant life.

Myron L Company has two proven ways to measure such impurities.  Our DS Meters provide fast, accurate, on-the-spot measurement of total dissolved solids (TDS) or conductivity.  pDS Meters test conductivity or TDS, plus pH.  Readings from their highly stable circuitry help prevent equipment damage, assure product quality and verify in-line instrumentation in a wide range of applications.

Accurate readings in three easy steps:

1- Rinse and fill cell cup 
2- Select conductivity range
3- Push button and take reading


Reliability Built In

Breakage is one of the major causes of sensor failure in a typical pH or conductivity instrument.  Myron L instruments provide maximum protection for both the pH and the conductivity electrodes inside the cell cup.  The user-replaceable pH electrode features a chemical resistant, liquid junction.

Unique Field Tested Design

Our unique, durable, field tested design has evolved over more than 35 years, making Myron L instruments among the most reliable and popular of their kind in the world.

They're lightweight and compact, yet Myron L's DS and pDS Meters are also tough, with rugged, taut-band meter movements.

Model 532T1

Our most popular model for many years, this instrument offers three very useful ppm ranges. Like other three range and single range models, it features a unique electronic Internal Standard for easy and fast field calibration and range doubling.


Model 532T1

Model EP-10

With its four micromho ranges, this instrument is ideal for most water treatment applications. Its low range will accurately test boiler condensate; with the RE-10 Range Extender, it can check process solutions up to 100,000 micromhos.

 


Model EP-10

Model EP

The most versatile of all DS Meters, this instrument is capable of testing both ultra pure and ocean waters...and everything in between! It has five conductivity ranges for easy readability. The most sensitive range includes resistivity equivalents, making it ideal for DI water systems.


Model EP

Accessories


NIST Standard Solutions and pH Buffers

All Myron L instruments are factory calibrated with standard solutions of known conductivity/TDS value and (when appropriate) with pH buffer values 4, 7, 10.  These solutions and buffers are traceable to the U.S. Government's National Institute of Standards and Technology primary solutions. Your instruments will be kept most accurate by periodic recalibration with the appropriate Conductivity Standard Solution and pH Buffers. See table below for recommendations.  NOTE: pH 7 buffer is especially important and should be used every 1-2 weeks.

 


Porta-Kit with EP11/pH


Range Extender

Model RE-10 increases the conductivity/TDS range 10 times when inserted into the sample-filled cell cup.  Not available for Model 512T10.

Porta-Kit
(pDS only). Sturdy foam-lined case with 2 oz. bottles of pH 4, 7 and 10 buffers and conductivity standard solution. (Order Model PK3 for Models M6/pH, T2/pH and T6/pH; Model PK7 for Model EP11/pH)

Porta-Pak Carrying Case
can be used with all DS and pDS Meters. Foam-lined and molded of sturdy ABS plastic. No solutions/buffers included. Model: PTP 

Replacement pH Sensor
Model RPY is a unique non-refillable KCI gel-filled combination pH electrode featuring a unique liquid junction. Complete installation instructions included. Model: RPY

NIST Certification
Certificates are available which confirm NIST traceability of an instrument. (Order #MC) or standard solution/pH buffer (Order #SC).
Note: Both MC Meter Certificates and/or SC Solution Certificates must be specified when placing instrument/solution orders.


Instrument Specifications

Ranges   pH - 2-12 pH (pDS Meters only)
Conductivity 1, 3, 4 or 5 depending on model (see table below)
Readout 2 1/2" taut-band shock resistant meter
Units of Measure Choice of parts per million (ppm)/TDS or micromhos/(microsiemens µS) conductivity
Accuracy
               
pH - ±0.2 pH units
Conductivity - ±2% full scale
Repeatability ±1%
Temperature Compensation Automatic (to 25ºC) for conductivity samples between 50° and 160°F
(10-71°C) Except EP which is 32º-120ºF (0-49ºC)
Calibration Controls Conductivity, pH Zero, and pH Gain
Electrodes 
(built-in)
pH - KCl gel-filled, field replaceable
Conductivity - Never need replatinizing
Cell Cup Chip and crack resistant polyethylene
Circuitry Very stable - requires minimal recalibration
Batteries One or two 9-volt batteries supplied, good for 2000 tests/1 year
Dimensions 3.4"W x 4.5"D x 4.0"H (85 x 129 x 126 mm)
Weight One pound (0.45 kg)

DS Meters

Model 512T4* 512M5* 512T5* 512T10* 532M1* 532T1* 532T2* EP-10 EP
Ranges 0-2500 0-5000 0-5000 0-10,000 0-50 0-50 0-25 0-10 0-0.5
0-500 0-500 0-250 0-100 0-5
0-5000 0-5000 0-2500 0-1000 0-50
0-10,000 0-500
0-5000
Units Measured ppm** µM ppm ppm** µM ppm ppm µM µM, MW

Recommended NIST Standard Solutions

Key (see below) F G or N G O B,D,G B,D,G A,C,F K,M,O B,D,G

* These models feature the Internal Standard for easy field conductivity calibration & range doubling.
** Also available in micromhos/microsiemens

NIST Standard Solutions

Key

Order #

Values

A 442-15 (15 ppm/23.8 µS)
B 442-30 (30 ppm/47 µS)
C 442-150 (150 ppm/229 µS)
D 442-300 (300 ppm/445 µS)
E 442-1000 (1000 ppm/1417 µS)
F 442-1500 (1500 ppm/2060 µS)
G 442-3000 (3000 ppm/3900 µS)
H 442-15,000 (15,000 ppm/16,630 µS)
I 442-30,000 (30,000 ppm/30,100 µS)
J KCl-18 (11 ppm/18 µS)
K KCl-70 (45 ppm/70 µS)
L KCl-180 (116 ppm/180 µS)
M KCl-700 (478 ppm/700 µS)
N KCl-1800 (1294 ppm/1800 µS)
O KCl-7000 (5687 ppm/7000 µS)
P KCl-18,000 (16,462 ppm/18,000 µS)

pH Buffers

pH4

pH7

pH10

Storage Solution


pDS Meters

Model T6/pH* M6/pH T2/pH* EP11/pH
Ranges 2-12 pH 2-12 pH 2-12 pH 2-12 pH
0-5000 ppm 0-5000 µM 0-50 ppm 0-10 µM
0-500 ppm 0-100 µM
0-5000 ppm 0-1000 µM
0-10,000 µM
Units Measured pH, ppm pH, µM pH, ppm pH, µM

Recommended NIST Standard Solutions
(All pDS Models Also Use 4, 7, 10 pH Buffers)

Key (see left)

G G B,D,G K,M,O

Portable pH, Conductivity, TDS & DS, pDS Meters


Site Designed And Maintained By Panther Marketing And Design