Large dual LCD shows pH (or ORP) and temperature simultaneously
|
|
|
Two set point, two SPDT relay for on/off control
|
|
|
Symmetrical mode operation eliminates electrical noise
|
|
|
HOLD feature deactivates relays on contact closure; ideal for float switches or dual controller applications
|
|
|
0 to 2000 second time delay adjustment on all relays
|
|
|
Separately adjustable high and low set point hysteresis bands prevent rapid contact switching near set points
|
|
|
Push button two-point calibration and electrode offset adjustment
|
|
|
Protected against electromagnetic interference
|
|
|
LED indicators signal control activities to monitor controller status
|
|
|
Battery back-up of memory maintains set-up if power fails
|
The pH 800 controller provides ±0.01 pH accuracy for reliable, easy-to-use on/off control of your pH and mV process. Two separately programmable relays are ideal for acid feed/base feed applications. Use the isolated 4-20 mA output to send data to your recorder or data acquisition system for hard copy reports.
|
|
Customize your controller to fit your exact application! This unit is selectable for pH or ORP (mV) control and manual or automatic temperature compensation. The 1/4 DIN size fits into standard panel cutouts. IP54 rated front panel keypad is weather resistant. Mounting hardware included.
Click below to download Acrobat (.pdf) file of:
pH 800 controller Product Bulletin
pH 800 Controller Manual
|
Measures
|
pH, mV, °C
|
|
pH Range
|
0.00 to 14.00 pH
|
|
pH Resolution
|
0.01 pH
|
|
pH Accuracy
|
±0.01 pH
|
|
pH Calibration
|
one or two points (select from pH 1.00, 4.01, 6.86, 7.00, 9.00, 9.18, or 10.00)
|
|
mV Range
|
±1000 mV
|
|
mV Resolution
|
1 mV
|
|
mV Accuracy
|
±1 mV
|
|
mV Calibration
|
mV offset
|
|
Temperature Range
|
-9.9 to 125°C
|
|
Temperature Resolution
|
0.1°C
|
|
Temperature Accuracy
|
±0.1°C
|
|
Temperature Calibration
|
offset up to ±5°C
|
|
Control type
|
on/off
|
|
Number of inputs
|
one
|
|
Number of set points
|
two (high and low)
|
|
Separate alarm relay
|
no
|
|
Output Control
|
2 SPDT relays, 6 A at 110 VAC, 250 VAC maximum
|
|
Output Current
|
isolated 4-20 mA, 600 W maximum load
|
|
Hysteresis
|
0.1 to 1.0 pH, 10 to 100 mV, or 1 to 10%
|
|
Relay delay
|
selectable, 0 to 2000 seconds
|
|
Input impedance
|
10^6 MW
|
|
Electrical isolation
|
yes, galvanically
|
|
Temperature Sensor
|
100 W or 1000 W Pt RTD
|
|
Temperature Compensation
|
Automatic or manual from -9.9 to 125°C
|
|
Password protection
|
two level password
|
|
Display
|
dual line LCD, 4-digit upper and 3 1/2 digit lower
|
|
Operating Temperature
|
-10 to 60°C
|
|
Housing
|
1/4 DIN
|
|
Dimensions
|
3.8" x 3.8" x 6.9" (9.6 x 9.6 x 17.5 cm)
|
|
Shipping weight
|
2.5 lbs (1.2 kg)
|