Benchtop Conductivity Meter,CON 510,Oakton Instruments

BenchtopConductivity Meter CON 510 from Oakton Instruments





Benchtop Conductivity Meter CON510 from Oakton Instruments

Backto Conductivity Benchtop Meters

CON510 Benchtop Conductivity Meter

Anaffordable way to take consistent, accurate conductivity measurementsin your laboratory

 

 

 

 

Dualdisplay shows both conductivity or TDS and temperaturein °C or °F
Single-and multi-point automatic or manual calibration: customizemeter calibration for quick checks or for best meter accuracy
Autoranging across five ranges: offers the best resolutionfor your measurements
Advancedset up mode: recalls previous calibration data, conductivity/TDSeffective cell constants per range, and more
Built-innon-volatile memory: stores up to 50 conductivity or TDSreadings with corresponding temperature
Automaticor manual temperature compensation
Selectablecell constant
Adjustableconductivity to TDS conversion factor and temperaturecoefficient: gives highest accuracy in any solution
Selectablenormalization temperature: choose between 15°C and20°C
Built-inelectrode holder arm; selectable "Ready" indicator;Hold function; diagnostic error messages
IncludesWD-35608-50 conductivity cell
Measures Conductivity,TDS, °C, °F
ConductivityRange 0to 19.99
0 to 199.9
0 to 1999 µS
0 to 19.99 mS
0 to 199.9 mS
ConductivityResolution 0.01µS
0.1 µS
1 µS
0.01 mS
0.1 mS
ConductivityAccuracy ±1%full scale or ±1 digit
ConductivityCalibration Automatic:single or multi-point up to 4 points (84 µS,1413 µS, 12.88mS, 111.8 mS)
Manual: single or multi-point up to 5 points (one userselectable point per range for multi-point calibration)
TDSRange 0.00to 9.99 ppm
10.0 to 99.9 ppm
100 to 999 ppm
1.00 to 9.99 ppt
10.0 to 99.9 ppt
100 to 200 ppt
TDSResolution 0.01ppm
0.1 ppm
1 ppm
0.01 ppt
0.1 ppt
TDSAccuracy ±1%full scale or ±1 digit
TDSCalibration Automatic:single or multi-point up to 4 points (84µS, 1413µS, 12.88mS,111.8mS)
Manual: single or multi-point up to 5 points (one userselectable point per range for multi-point calibration)
TemperatureRange 0.0to 100.0°C
32 to 212.0°F
TemperatureResolution 0.1°Cor °F
TemperatureAccuracy ±0.5°Cor ±0.9°F
TemperatureCalibration offset0.1° increments up to ±5°
Memory upto 50 sets with temp
Cellconstant selectable0.1, 1.0, 10
Temperaturecoefficient adjustablefrom 0 to 10% per °C or °F
Dimensions 9"Wx 2-3/8"H x 7"D
Shippingweight meteronly 1.25 lbs. (0.6 kg); boxed 3 lbs (1.4 kg)