The general purpose two-wire capacitance transmitter provides contact level measurement up to 10' or 3m, and is ideally suited for clean, water-based, non-coating corrosive liquids with constant chemistry. The transmitter is typically selected for pressurized day tank and process vessel applications. Media examples include nitric and hydrochloric acid.
Features
FEP probe for use with highly corrosive acid solutions
Self grounding probe does not require reference in plastic tanks
Easy potentiometer calibration with power LED and span invert switch
Small probe mounts in 3/4" fitting
Tech Tip
For remote relay control and indication, package your level transmitter with the LC52-1001 continuous relay controller. The spanable controller features up to three process set points with two relay outputs and an isolated 4-20 mA repeater.