Temperature Transmitters - DIN Mount, Head Mounted

DIN Mount Transmitters

V 608 Temperature Transmitter

Input:

Thermocouple, RTD

Output:

4-20 mA
  • PC Programmable
  • Programmable Sensor Fault Response
  • Non-Isolated
  • 12-30 VDC Loop-Powered
Specifications   Instructions

 

V 611 Ultra-Slim Temperature Transmitter

Input:

Thermocouple, RTD

Output:

4-20 mA
  • 9 mm (0.35") wide

  • PC Programmable

  • Reverse Output Capable (20-4 mA)

  • 100 Ohm RTD, 2, 3, or 4-wire

  • T/C J, K, T, E, R, S,N, B, L, U, W5, W3

  • Input Linearization

  • Non-Isolated

  • Internal or External CJC

  • Supply Voltage:12-30 VDC from Output Loop


Specifications   Instructions

 

V 624 Programmable Temperature Transmitter

Input:

Thermocouple, RTD,
Thermistor, Custom

Output:

0-2 mA to 0-20 mA, 20-0 mA
0-1 V to 0-10 V, 10-0 V
  • PC Programmable
  • Reverse Output Programmable
  • Custom Input Linearization
  • Programmable Sensor Fault Response
  • Removeable Plugs
  • 3.7 kV Input/Output/Power Isolation
  • Supply Voltage: 24-60 or 85-230 VAC/VDC
Specifications   Instructions

 

V 604s Programmable Universal Transmitter

Two
Inputs:

±1000 mVDC to ±300 VDC
±50 mADC
Thermocouple, RTD,
Thermistor or Potentiometer 0-5k Ω

Two Outputs:
(common ground)

0-5 mA to ±40 mA
0-4 V to -12-15 V
One relay
Modbus communications
 
  • PC Programmable
  • Unipolar or Bipolar Input and Output
  • Reverse Output Programmable
  • Custom Input Linearization
  • Programmable Alarm Relay
  • 3.7 kV Input/Output/Power Isolation
  • Supply Voltage: 24-60 or 85-230 VAC/VDC

Specifications    Instructions
 

V 604 Programmable Universal Transmitter

Input:

0-2 mV to ±40 V
0-80 µA to -50-100 mA
Thermocouple, RTD,
Thermistor, Potentiometer

Output:

0-5 mA to ±40 mA
0-4 V to -12-15 V
 
  • PC Programmable
  • Unipolar or Bipolar Input and Output
  • Reverse Output Programmable
  • Custom Input Linearization
  • Programmable Alarm Relay
  • 3.7 kV Input/Output/Power Isolation
  • Supply Voltage: 24-60 or 85-230 VAC/VDC
Specifications    Instructions

VC 603 Programmable Universal Transmitter with Alarms

Input:

0-2 mV to ±40 V
0-80 µA to -50-100 mA
Thermocouple, RTD,
Thermistor, Potentiometer

Output:

0-5 mA to ±40 mA
0-4 V to
-12-15 V
1 DPDT, 2 SPDT

  • PC Programmable
  • 3 Independently Configurable Alarm Contacts
  • Unipolar or Bipolar Input and Output
  • Reverse Output Programmable
  • Custom Input Linearization
  • 3.7 kV Input/Output/Power Isolation
  • Supply Voltage: 24-60 or 85-230 VAC/VDC
Specifications    Instructions

Head Mounted Transmitters

VK 616 Temperature Transmitter

Input:

Thermocouple, RTD

Output:

4-20 mA

  • PC Programmable
  • Programmable Sensor Fault Response
  • Isolated and Non-Isolated Versions
  • 12-30 VDC Loop-Powered
Specifications  Instructions

VK 626  HART Temperature Transmitter

Input:

Thermocouple, RTD

Output:

4-20 mA

  • PC Programmable
  • HART Protocol
  • Programmable Sensor Fault Response
  • Isolated
  • 12-30 VDC Loop-Powered

Specifications   Instructions

VK 636 Profibus Temperature Transmitter

Input:

Thermocouple, RTD

Output:

Profibus PA

  • PC Programmable
  • Profibus Process Automation Protocol
  • Programmable Sensor Fault Response
  • Isolated
 

B 840 Multi-Channel Loop Power Supply

Input:

24, 115, or 230 VAC

Output:

4-20 mA, 24 VDC

  • 4-Channel 4-20 mA, 24V DC Versions
  • LED Monitor for Each Channel
  • Each Channel Isolated
  • Supply Voltage: 24, 115, or 230 VAC 50/60 Hz
  • 30 mA Current Limiter for Each Channel
Specifications    Instructions

B 812 Loop Power Supply with Signal Output and HART Communications

Input:

4-20 mA, 18 to 25.5 VDC
Source resistance 330 Ω

Output:

4-20 mA, 17 VDC no load
Permitted load: 750 Ω, 550 Ω with HART
  • 3.6 kV Input, Output, and Power Isolation
  • Red LED for Open and Short Circuit Fault Detection
  • Designed for HART Protocol
  • Supply Voltage: 20-70 or 60-265 VAC/VDC (45-400 Hz for AC)

Specifications   Instructions    Brochure

Back To API-Camille Bauer