DC to DC Transmitters
|
Looptracker® LED
s
Push to Test Built-In Loop Power Supply Lifetime Warranty
|
|
Model
|
Input
|
Output Ranges
|
Features
|
Data & Applications
|
Photo
|
API 4010 G
Non-Isolated DC-DC Transmitter
with Loop Power Supply
Specify Input, Output & Power
|
Factory Configured Others available 0-100mVDC to 0-500VDC ±100mVDC to ±10VDC 0-1mADC to 0-900mADC
|
Factory Configured Others available 0-1V 0-5V 1-5V 0-10V ±5V ±10V 0-1mA 0-20mA 4-20mA
|
Hot-Swappable Plug-In Design Looptracker® LEDs for Input and Output Push to Test 18 V Loop Power Supply Uses 8-Pin Socket
|
Data Sheet
Applications
Convert a Control Signal for a Process
Reference
Ground Loops
RFI / EMI
|
|
API 4050 G
Non-Isolated DC-DC Transmitter
Narrow Input Span
with Loop Power Supply
Specify Input, Output & Power
|
Factory Configured Others available 0-10mVDC to 0-100mVDC ±50mVDC 0-100ADC to 0-1mADC
|
Factory Configured Others available 0-1V 0-5V 1-5V 0-10V ±5V ±10V 0-1mA 0-20mA 4-20mA
|
Hot-Swappable Plug-In Design Looptracker® LEDs for Input and Output Push to Test 18 V Loop Power Supply Uses 8-Pin Socket
|
Data Sheet
Reference
Ground Loops
RFI / EMI
|
|
API 4300 G
Isolated DC-DC Transmitter
with Loop Power Supply
Specify Input, Output & Power
|
Factory Configured Others available 0-100mVDC to 0-500VDC ±100mVDC - ±10VDC 0-1mADC to 0-900mADC
|
Factory Configured Others available 0-1V 0-5V 1-5V 0-10 ±5V ±10V 0-1mA 0-20mA 4-20mA
|
Hot-Swappable Plug-In Design Looptracker® LEDs for Input and Output Push to Test Full Isolation 18 V Loop Power Supply Uses 8-Pin Socket
|
Data Sheet
Applications
Motor Load Control Monitoring Motor Speed with a PLC
Manual Override of Computer Control
Monitoring Pressure w. a PLC
Monitoring Product Moved by Conveyor
Phase Separator Water Level Control
Reference
Ground Loops
RFI / EMI
|
|
API 4310 G
Isolated DC-DC Transmitter
Narrow Input Span with Loop Power Supply
Specify Input, Output & Power
|
Factory Configured Others available 0-10mVDC to 0-100mVDC ±50mVDC 0-100ADC to 0-1mADC
|
Factory Configured Others available 0-1V 0-5V 1-5V 0-10V ±5V ±10V 0-1mA 0-20mA 4-20mA
|
Hot-Swappable Plug-In Design Looptracker® LEDs for Input and Output Push to Test Full Isolation 18 V Loop Power Supply Uses 8-Pin Socket
|
Data Sheet
Reference
Ground Loops
RFI / EMI
|
|
API 4380 G
Field Selectable
Isolated DC-DC Transmitter
with Loop Power Supply
Specify Power
|
24 Field Settable
0-50mVDC to ±10VDC 0-1mADC to 0-20mADC Others available
|
16 Field Settable
0-1V to ±10V 0-2mA to 0-20mA 4-20mA
|
Minuteman Setup Hot-Swappable Plug-In Design Looptracker® LEDs for Input and Output Push to Test Full Isolation 18 V Loop Power Supply Uses 8-Pin Socket
|
Data Sheet
Help Sheet
Range Settings
Reference
Ground Loops
RFI / EMI
|
|
API 4380 GHV
3
Field Selectable
Isolated DC-DC Transmitter
High Voltage Input
Specify Power
|
24 Field Settable
0-1VDC to ±200VDC Others available
|
16 Field Settable
0-1V to ±10V 0-2mA to 0-20mA 4-20mA
|
Minuteman Setup Hot-Swappable Plug-In Design Looptracker® LEDs for Input and Output Push to Test Full Isolation Uses 8-Pin Socket
|
Data Sheet
Range Settings
Reference
Ground Loops
RFI / EMI
|
|
API 4380 DIN
Field Selectable
Isolated DC-DC Transmitter
80-265 VAC or 48-300 VDC Powered
|
24 Field Settable
0-50mVDC to ±10VDC 0-1mADC to 0-20mADC Others available
|
16 Field Settable
0-1V to ±10V 0-2mA to 0-20mA 4-20mA
|
Minuteman Setup
Looptracker® LEDs for Input and Output Push to Test Full Isolation 12 V Loop Power Supply DIN package 22.5 mm W Universal Power
|
Data Sheet
Help Sheet
Applications
Controlling and Monitoring Liquid Flow From a Single Flow Meter
Reference
Ground Loops
RFI / EMI
|
|
API 4380 DIN DD
Field Selectable
Isolated DC-DC Transmitter
9-30 VDC Powered
|
API 4385 G
Field Selectable
Isolated DC-DC Transmitter
Wide Ranging w. Input Offset with Loop Power Supply
Specify Power
|
24 Field Settable
0-50mVDC to 0-20VDC 0-200µADC to 0-40mADC Others available Selectable Zero Offset
|
16 Field Settable
0-1V to ±10V 0-2mA to 0-20mA 4-20mA
|
Minuteman Setup
Hot-Swappable Plug-In Design Looptracker® LEDs for Input and Output Push to Test Full Isolation 18 V Loop Power Supply Uses 8-Pin Socket
|
Data Sheet
Range Settings
Reference
Ground Loops
RFI / EMI
|
|
DPI HV-DC
Factory Set
Field
Changeable
Isolated DC-DC Transmitter
High Voltage Input Specify Input, Output &
115 VAC or 230 VAC Powered
|
7 Standard, 1 Custom
Factory set, can be changed in the field 0-100VDC to 0-2000VDC
|
16 Ranges
Factory set, can be changed in the field
0-1V to ±10V 0-2mA to 0-20mA 4-20mA
|
Looptracker® LEDs for Input and Output Push to Test Full Isolation 2000V Isolation DIN package 55 mm W
|
Data Sheet
Range Settings
Reference
Ground Loops
RFI / EMI
|
|
API 4390
Factory Set
2 Channel DC-DC Transmitter Isolator
Specify Input, Output & Power
|
Factory Configured DC Volts or mA 2 Independent Channels 0-100mVDC to 0-100VDC 0-1mADC to 4-20 mADC
|
Factory Configured DC Volts or mA 2 Independent Channels 0-100mVDC to 0-100VDC 0-1mADC to 4-20 mADC
|
Looptracker® LEDs for Input and Output Push to Test Full Isolation 2000V Isolation DIN package 55 mm W
|
Data Sheet
Reference
Ground Loops
RFI / EMI
|
|
API 4391
Factory Set
2 Channel DC-DC Transmitter Isolator
Specify Input, Output & Power
|
Factory Configured DC Volts or mA 2 Independent Channels 0-100mVDC to 0-100VDC 0-1mADC to 4-20 mADC
|
Factory Configured Bipolar DC Volts 2 Independent Channels ±5VDC, ±10VDC Others Available
|
Looptracker± LEDs for Input and Output Push to Test Full Isolation 2000V Isolation DIN package 55 mm W
|
Data Sheet
Reference
Ground Loops
RFI / EMI
|
|
API 4392
Factory Set
2 Channel DC-DC Transmitter Isolator
Specify Input, Output & Power
|
Factory Configured Bipolar DC Volts or mA 2 Independent Channels ±5VDC, ±10VDC Others Available
|
Factory Configured Bipolar DC Volts or mA 2 Independent Channels ±5VDC, ±10VDC Others Available
|
Looptracker® LEDs for Input and Output Push to Test Full Isolation 2000V Isolation DIN package 55 mm W
|
Data Sheet
Reference
Ground Loops
RFI / EMI
|
|
API 4393
IsoSplitter
Factory Set
DC-DC Signal Splitter Isolator
Specify Input, Output & Power
|
Factory Configured Others available 0-50mVDC to ±10VDC 0-1mADC to 0-20mADC, 4-20mADC
|
Factory Configured 2 Independent Channels 0-50mVDC to ±10VDC 0-1mADC to 0-20mADC, 4-20mADC Others available
|
Looptracker® LEDs for Input and Output Push to Test Full Isolation 2000V Isolation DIN package 55 mm W
|
Data Sheet
Reference
Ground Loops
RFI / EMI
|
|
API 4393 L1
IsoSplitter
4-20 mA
DC-DC Signal Splitter Isolator
Specify Power
|
Factory Configured 4-20 mA 18 V Source
|
Factory Configured 2 Independent Channels Ch.1: 4-20 mA 18 V Source Ch.2: 4-20 mA 18 V Source
|
Looptracker® LEDs for Input and Output Push to Test Full Isolation 2000V Isolation DIN package 55 mm W
|
Data Sheet
Reference
Ground Loops
RFI / EMI
|
|
API 4393 L1 EX1
IsoSplitter
4-20 mA
DC-DC Signal Splitter Isolator
Specify Power
|
Factory Configured 4-20 mA 18 V Source
|
Factory Configured 2 Independent Channels Ch.1: 4-20 mA Current Sinking Ch.2: 4-20 mA 18 V Source
|
Looptracker® LEDs for Input and Output Push to Test Full Isolation 2000V Isolation DIN package 55 mm W
|
Data Sheet
Reference
Ground Loops
RFI / EMI
|
|
API 4393 L1 EX2
IsoSplitter
4-20 mA
DC-DC Signal Splitter Isolator
Specify Power
|
Factory Configured 4-20 mA 18 V Source
|
Factory Configured 2 Independent Channels Ch.1: 4-20 mA 18 V Source Ch.2: 4-20 mA Current Sinking
|
Looptracker® LEDs for Input and Output Push to Test Full Isolation 2000V Isolation DIN package 55 mm W
|
Data Sheet
Reference
Ground Loops
RFI / EMI
|
|
API 4393 L1 EX3
IsoSplitter
4-20 mA
DC-DC Signal Splitter Isolator
Specify Power
|
Factory Configured 4-20 mA 18 V Source
|
Factory Configured 2 Independent Channels Ch.1: 4-20 mA Current Sinking Ch.2: 4-20 mA Current Sinking
|
Looptracker® LEDs for Input and Output Push to Test Full Isolation 2000V Isolation DIN package 55 mm W
|
Data Sheet
Reference
Ground Loops
RFI / EMI
|
|
LPI-1
Loop-Powered Isolator
|
Factory Configured 4-20 mA Others Available
|
Factory Configured 4-20 mA Others Available
|
Hot-Swappable Plug-In Design Looptracker® LED for Output Push to Test Uses 8-Pin Socket
|
Data Sheet
Applications
Monitor & Record Mass Flow & Ratio
Reference
Ground Loops
RFI / EMI
|
|
LPI-2
Loop-Powered Isolator, 2 Independent Channels
|
Factory Configured 2 Independent 4-20 mA Others Available
|
Factory Configured 2 Independent 4-20 mA Others Available
|
DPI-2
Loop-Powered Isolator, 2 Channel
|
Factory Configured 2 Independent 4-20 mA Others Available
|
Factory Configured 2 Independent 4-20 mA Others Available
|
Looptracker® LED for Output Push to Test DIN package 22.5 mm W
|
Data Sheet
Applications
Monitor & Record Mass Flow & Ratio
Reference
Ground Loops
RFI / EMI
|
|