DC To DC Transmitters

 DC to DC Transmitters   Looptracker® LED s
  Push to Test
  Built-In Loop Power Supply
  Lifetime Warranty
Model
Input
Output Ranges
Features
Data & Applications
Photo
API 4010 G
Non-Isolated DC-DC Transmitter
with Loop Power Supply
Specify Input, Output & Power
Factory Configured
Others available
0-100mVDC to
0-500VDC
±100mVDC to ±10VDC
0-1mADC to
0-900mADC
Factory Configured
Others available
0-1V
0-5V
1-5V
0-10V
±5V
±10V
0-1mA
0-20mA
4-20mA
Hot-Swappable Plug-In Design
Looptracker® LEDs for
Input and Output
Push to Test
18 V Loop Power Supply
Uses 8-Pin Socket

Data Sheet

Applications
Convert a Control Signal for a Process

Reference

Ground Loops
RFI / EMI

API 4050 G
Non-Isolated DC-DC Transmitter
Narrow Input Span
with Loop Power Supply
Specify Input, Output & Power
Factory Configured
Others available
0-10mVDC to
0-100mVDC
±50mVDC
0-100ADC to
0-1mADC
Factory Configured
Others available
0-1V
0-5V
1-5V
0-10V
±5V
±10V
0-1mA
0-20mA
4-20mA
Hot-Swappable Plug-In Design
Looptracker® LEDs for
Input and Output
Push to Test
18 V Loop Power Supply
Uses 8-Pin Socket
Data Sheet

Reference

Ground Loops
RFI / EMI
API 4300 G
Isolated DC-DC Transmitter
with Loop Power Supply
Specify Input, Output & Power
Factory Configured
Others available
0-100mVDC to
0-500VDC
±100mVDC - ±10VDC
0-1mADC to
0-900mADC
Factory Configured
Others available
0-1V
0-5V
1-5V
0-10
±5V
±10V
0-1mA
0-20mA
4-20mA
Hot-Swappable Plug-In Design
Looptracker® LEDs for
Input and Output
Push to Test
Full Isolation
18 V Loop Power Supply
Uses 8-Pin Socket
Data Sheet

Applications

Motor Load Control
Monitoring Motor Speed with a PLC
Manual Override of Computer Control
Monitoring Pressure w. a PLC
Monitoring Product Moved by Conveyor

Phase Separator Water Level Control

Reference

Ground Loops
RFI / EMI
API 4310 G
Isolated DC-DC Transmitter
Narrow Input Span
with Loop Power Supply

Specify Input, Output & Power
Factory Configured
Others available
0-10mVDC to
0-100mVDC
±50mVDC
0-100ADC to
0-1mADC
Factory Configured
Others available
0-1V
0-5V
1-5V
0-10V
±5V
±10V
0-1mA
0-20mA
4-20mA
Hot-Swappable Plug-In Design
Looptracker® LEDs for
Input and Output
Push to Test
Full Isolation
18 V Loop Power Supply
Uses 8-Pin Socket
Data Sheet

Reference

Ground Loops
RFI / EMI
API 4380 G
Field Selectable
Isolated DC-DC Transmitter
with Loop Power Supply
Specify Power
24 Field Settable
0-50mVDC to
±10VDC
0-1mADC to
0-20mADC
Others available
16 Field Settable
0-1V to ±10V
0-2mA to 0-20mA
4-20mA
Minuteman Setup
Hot-Swappable Plug-In Design
Looptracker® LEDs for
Input and Output
Push to Test
Full Isolation
18 V Loop Power Supply
Uses 8-Pin Socket
Data Sheet

Help Sheet

Range Settings

Reference

Ground Loops
RFI / EMI
API 4380 GHV 3
Field Selectable
Isolated DC-DC Transmitter
High Voltage Input
Specify Power
24 Field Settable
0-1VDC to
±200VDC
Others available
16 Field Settable
0-1V to ±10V
0-2mA to 0-20mA
4-20mA
Minuteman Setup
Hot-Swappable Plug-In Design
Looptracker® LEDs for
Input and Output
Push to Test
Full Isolation
Uses 8-Pin Socket
Data Sheet

Range Settings

Reference

Ground Loops
RFI / EMI
API 4380 DIN
Field Selectable
Isolated DC-DC Transmitter

80-265 VAC or 48-300 VDC Powered
24 Field Settable
0-50mVDC to
±10VDC
0-1mADC to
0-20mADC
Others available
16 Field Settable
0-1V to ±10V
0-2mA to 0-20mA
4-20mA
Minuteman Setup
Looptracker® LEDs for
Input and Output
Push to Test
Full Isolation
12 V Loop Power Supply
DIN package 22.5 mm W
Universal Power
Data Sheet

Help Sheet

Applications

Controlling and Monitoring Liquid Flow From a Single Flow Meter

Reference

Ground Loops
RFI / EMI
API 4380 DIN DD
Field Selectable
Isolated DC-DC Transmitter

9-30 VDC Powered
API 4385 G
Field Selectable
Isolated DC-DC Transmitter

Wide Ranging w. Input Offset
with Loop Power Supply

Specify Power
24 Field Settable
0-50mVDC to
0-20VDC
0-200µADC to
0-40mADC
Others available
Selectable Zero Offset
16 Field Settable
0-1V to ±10V
0-2mA to 0-20mA
4-20mA
Minuteman Setup
Hot-Swappable Plug-In Design
Looptracker® LEDs for
Input and Output
Push to Test
Full Isolation
18 V Loop Power Supply
Uses 8-Pin Socket
Data Sheet

Range Settings

Reference

Ground Loops
RFI / EMI
DPI HV-DC
Factory Set
Field
Changeable
Isolated DC-DC Transmitter
High Voltage Input
Specify Input, Output & 115 VAC or 230 VAC Powered
7 Standard,
1 Custom
Factory set, can be changed in the field
0-100VDC to
0-2000VDC
16 Ranges
Factory set, can be changed in the field
0-1V to ±10V
0-2mA to 0-20mA
4-20mA
Looptracker® LEDs for
Input and Output
Push to Test
Full Isolation
2000V Isolation
DIN package 55 mm W
Data Sheet

Range Settings

Reference

Ground Loops
RFI / EMI
API 4390
Factory Set
2 Channel DC-DC Transmitter Isolator
Specify Input, Output &  Power
Factory Configured
DC Volts or mA
2 Independent Channels
0-100mVDC to
0-100VDC
0-1mADC to 4-20 mADC
Factory Configured
DC Volts or mA
2 Independent Channels
0-100mVDC to
0-100VDC
0-1mADC to 4-20 mADC
Looptracker® LEDs for
Input and Output
Push to Test
Full Isolation
2000V Isolation
DIN package 55 mm W
Data Sheet

Reference
Ground Loops
RFI / EMI
API 4391
Factory Set
2 Channel DC-DC Transmitter Isolator
Specify Input, Output &  Power
Factory Configured
DC Volts or mA
2 Independent Channels
0-100mVDC to
0-100VDC
0-1mADC to 4-20 mADC
Factory Configured
Bipolar DC Volts
2 Independent Channels
±5VDC, ±10VDC
Others Available
Looptracker± LEDs for
Input and Output
Push to Test
Full Isolation
2000V Isolation
DIN package 55 mm W
Data Sheet

Reference
Ground Loops
RFI / EMI
API 4392
Factory Set
2 Channel DC-DC Transmitter Isolator
Specify Input, Output &  Power
Factory Configured
Bipolar DC Volts or mA
2 Independent Channels
±5VDC, ±10VDC
Others Available
Factory Configured
Bipolar DC Volts or mA
2 Independent Channels
±5VDC, ±10VDC
Others Available
Looptracker® LEDs for
Input and Output
Push to Test
Full Isolation
2000V Isolation
DIN package 55 mm W
Data Sheet

Reference
Ground Loops
RFI / EMI
API 4393
IsoSplitter
Factory Set
DC-DC Signal Splitter Isolator
Specify Input, Output &  Power
Factory Configured
Others available
0-50mVDC to
±10VDC
0-1mADC to
0-20mADC,
4-20mADC
Factory Configured
2 Independent Channels
0-50mVDC to
±10VDC
0-1mADC to
0-20mADC,
4-20mADC
Others available
Looptracker® LEDs for
Input and Output
Push to Test
Full Isolation
2000V Isolation
DIN package 55 mm W
Data Sheet

Reference
Ground Loops
RFI / EMI
API 4393 L1
IsoSplitter
4-20 mA
DC-DC Signal Splitter Isolator
Specify Power
Factory Configured
4-20 mA
18 V Source
Factory Configured
2 Independent Channels
Ch.1: 4-20 mA
18 V Source
Ch.2: 4-20 mA
18 V Source
Looptracker® LEDs for
Input and Output
Push to Test
Full Isolation
2000V Isolation
DIN package 55 mm W
Data Sheet

Reference
Ground Loops
RFI / EMI
API 4393 L1 EX1
IsoSplitter
4-20 mA
DC-DC Signal Splitter Isolator
Specify Power
Factory Configured
4-20 mA
18 V Source
Factory Configured
2 Independent Channels
Ch.1: 4-20 mA
Current Sinking
Ch.2: 4-20 mA
18 V Source
Looptracker® LEDs for
Input and Output
Push to Test
Full Isolation
2000V Isolation
DIN package 55 mm W
Data Sheet

Reference
Ground Loops
RFI / EMI
API 4393 L1 EX2
IsoSplitter
4-20 mA
DC-DC Signal Splitter Isolator
Specify Power
Factory Configured
4-20 mA
18 V Source
Factory Configured
2 Independent Channels
Ch.1: 4-20 mA
18 V Source
Ch.2: 4-20 mA
Current Sinking
Looptracker® LEDs for
Input and Output
Push to Test
Full Isolation
2000V Isolation
DIN package 55 mm W
Data Sheet

Reference
Ground Loops
RFI / EMI
API 4393 L1 EX3
IsoSplitter
4-20 mA
DC-DC Signal Splitter Isolator
Specify Power
Factory Configured
4-20 mA
18 V Source
Factory Configured
2 Independent Channels
Ch.1: 4-20 mA
Current Sinking
Ch.2: 4-20 mA
Current Sinking
Looptracker® LEDs for
Input and Output
Push to Test
Full Isolation
2000V Isolation
DIN package 55 mm W
Data Sheet

Reference
Ground Loops
RFI / EMI
LPI-1
Loop-Powered Isolator
Factory Configured
4-20 mA
Others Available
Factory Configured
4-20 mA
Others Available
Hot-Swappable Plug-In Design
Looptracker® LED for Output
Push to Test
Uses 8-Pin Socket
Data Sheet

Applications

Monitor & Record Mass Flow & Ratio

Reference

Ground Loops
RFI / EMI
LPI-2
Loop-Powered Isolator,
2 Independent Channels
Factory Configured
2 Independent
4-20 mA
Others Available
Factory Configured
2 Independent
4-20 mA
Others Available
DPI-2
Loop-Powered Isolator, 2 Channel
Factory Configured
2 Independent
4-20 mA
Others Available
Factory Configured
2 Independent
4-20 mA
Others Available
Looptracker® LED for Output
Push to Test
DIN package 22.5 mm W
Data Sheet

Applications

Monitor & Record Mass Flow & Ratio

Reference

Ground Loops
RFI / EMI


Site Designed and Maintained By Panther Marketing & Design