Loop Power Supplies
Loop-Powered Isolator
Loop-Powered Transmitter
| Lifetime Warranty
|
|
Model
|
Input
|
Output Ranges
|
Features
| Data
& Applications
|
Photo
|
API
9046
Regulated DC Power Supply
Specify Input & Output Voltage
API 9046 CH
Regulated Bipolar DC Power Supply
Specify Input & Output Voltage
| Factory
Configured
115VAC or
230VAC
| Factory
Configured
Others available
9046-05 0-5V 250mA
9046-06 0-6V 200mA
9046-09 0-9V 150mA
9046-10 0-10V 140mA
9046-12 0-12V 125mA
9046-15 0-15V 100mA
9046-18 0-18V 85mA
9046-24 0-24V 75mA
9046-28 0-28V 60mA
9046-32 0-32V 50mA
9046 CH-05 ±5V 125mA
9046 CH-06 ±6V 100mA
9046 CH-09 ±9V 75mA
9046 CH-10 ±10V 70mA
9046 CH-12 ±12V 60mA
9046 CH-15 ±15V 50mA
| Hot-Swappable
Plug-In Design
Power LED
Output Fine Adjustment
Uses 8-Pin Socket
|
Data Sheet
Reference
Ohm's Law & Wire Resistance
| 
|
| Sineax
B 812
Loop Power Supply
with I/O Isolation
and Hart
| Factory
configured for
60-265 VAC or VDC power
| Input
side; 4-20 mA,
18 to 25.5 VDC
Source resistance
330 Ω
Output side; 4-20 mA,
17 VDC no load
Permitted load:
750 Ω
, 550 Ω
with HART
| 3.6
kV Input, Output, and Power
Isolation
Red LED for Open and Short
Circuit Fault Detection
Designed for HART Protocol
Specify Power, 60-265 VAC/VDC
or 20-70 VAC/VDC

Specifications
Instructions
|
Data
Sheet
Reference
Ground Loops |

|
| Sineax
B 812
Loop Power Supply
with I/O Isolation
and Hart
| Factory
configured for
20-70 VAC or VDC power
| Input
side; 4-20 mA,
18 to 25.5 VDC
Source resistance
330 Ω
Output side; 4-20 mA,
17 VDC no load
Permitted load:
750 Ω
, 550 Ω
with HART
| 3.6
kV Input, Output, and Powe
r Isolation
Red LED for Open and Short
Circuit Fault Detection
Designed for HART Protocol
Specify Power, 60-265 VAC/VDC
or 20-70 VAC/VDC

Specifications
Instructions
|
Data
Sheet
Reference
Ground Loops |

|
| Sineax
B 840
4 Channel Loop Power Supply
| Factory configured for
24 VAC,
115 VAC, or 230 VAC power
| 4-20 mA, 24 VDC
4 Independent 4-20 mA Loops
| 4-Channel 4-20 mA, 24V
DC Versions
LED Monitor for Each Channel
Each Channel Isolated
30 mA Current Limiter for Each Channel
Specify Power, 24 VAC, 115 VAC, or 230 VAC
Specifications
Instructions
|
Data
Sheet
Reference
Ground Loops
|

|
LPI-1
Loop-Powered Isolator
LPI-2
Loop-Powered Isolator, 2 Channel
| Factory Configured
Others Available
4-20 mA
| Factory Configured
Others available
4-20mA
| Hot-Swappable
Plug-In Design
Looptracker LED for Output
Push to Test
Uses 8-Pin Socket
| Data
Sheet
Applications
Monitor & Record Mass Flow & Ratio
Reference
Ground Loops
| 
|
DPI-2
Loop-Powered Isolator, 2 Channel
| Factory Configured
Others Available
4-20 mA
| Factory Configured
Others available
4-20mA
| Looptracker®
LED for Output
Push to Test
DIN package 22.5 mm W
| Data
Sheet
Applications
Monitor & Record Mass Flow & Ratio
Reference
Ground Loops
| 
|
Sineax
DCM 817-4
Loop-Powered Isolator

Sineax
DCM 817-5
PCB Mount Isolator 90° Pins
| 0-20
mA, 4-20 mA
| 0-20
mA, 4-20 mA
| 500
V Isolation
Circuit Board Mounted
Straight Pins or 90° Pins
Loop-Powered Passive Device
600 O Maximum Burden
Compact and Cost Effective
OEM Solution
Specifications |
Data
Sheet DCM 817-4
Data Sheet DCN 817-5
Applications
Monitor & Record Mass Flow & Ratio
Reference
Ground Loops |


|
Sineax
TI816
PCB Mount Isolator
Straight Pins

Sineax TI816
Loop-Powered Isolator
Voltage Output
| 0-20
mA, 4-20 mA
| 0-10
V to 2-10 V
| 500
V Isolation
Loop-Powered Passive Device
Order with V or mA Output
600 O Maximum Burden (Current)
500 O Maximum Burden (Voltage)
Only 0.5" (12.5 mm) Wide
Low Cost
Specifications
Instructions
|
Data
Sheet
Applications
Monitor & Record Mass Flow & Ratio
Reference
Ground Loops |

|
Sineax
SI 815
Loop-Powered Isolator
| 4-20
mA
| 4-20
mA
| 2300
V Isolation
Single and Two Channel Versions
Output Loop Powered (12-30 V)
Transfers Power to Input Loop
Optional HART Protocol
Specifications
Instructions
|
Data
Sheet
Applications
Monitor & Record Mass Flow & Ratio
Reference
Ground Loops |

|
Sineax
SI 815
2 Channel Loop-Powered Isolator
| 4-20
mA
| 4-20
mA
| 2300
V Isolation
Single and Two Channel Versions
Output Loop Powered (12-30 V)
Transfers Power to Input Loop
Optional HART Protocol
Specifications
Instructions
|
Data
Sheet
Applications
Monitor & Record Mass Flow & Ratio
Reference
Ground Loops |

|
Sineax
TI 807-5
Loop-Powered Isolator, 1 Channel
| 0-20
mA, 4-20 mA
| 0-20
mA, 4-20 mA
| Up
to 4000 V Isolation
Loop-Powered Passive Device
One, Two, or Three Channel Versions
1000 O Maximum Burden
Specifications
Instructions
|
Data
Sheet
Applications
Monitor & Record Mass Flow & Ratio
Reference
Ground Loops |

|
Sineax
TI 807-112
Loop-Powered Isolator
2 Channel

Sineax TI 807-113
Loop-Powered Isolator
3 Channel
| 0-20
mA, 4-20 mA
| 0-20
mA, 4-20 mA
| Up
to 4000 V Isolation
Loop-Powered Passive Device
One, Two, or Three Channel Versions
1000 O Maximum Burden
Specifications
Instructions |
Data
Sheet TI 807-112
Data Sheet TI 807-113
Applications
Monitor & Record Mass Flow & Ratio
Reference
Ground Loops |

|
|
|
|
|
|
|
|