When ordering Meter relays please include the following information.
- complete Meter relay model identification number
- direct drive, optemp or optronic
- choice of options
- single input information
Options
A-Input Power
A-00 Standard 115/230 VAC @ 47 to 63hz A-01 12 to 24 VDC A-10 -30 to +80VDC
B-Relay Operating Logic
B-00 Standard "Fail Safe" B-01 Reversed High and Low B-02 Reversed Low only (High-High) B-03 Reversed High only (Low-Low) B-04 Single High Construction, Low operation B-05 Delayed relay switching-single set pt. B-06 Delayed dual relay switching-double set pt. B-07 Delayed low relay switching-double set pt.
C-Load Relay Connection Configuration
C-20 Double Set Point (2 S.P.D.T. Relays) Single Set Point (1 D.P.D.T. Relay) C-21 D.P.D.T. Relay For Each Set Point C-22 D.P.D.T. High Relay, S.P.D.T. Low Relay C-23 S.P.D.T. High Relay D.P.D.T. Low Relay C-24 Signal Source For Remote Meter C-91 High relay output is reversed C-93 C-20 For Use With Option Board C-95 NO REAR TERMINAL BOARD OR WIRES C-97 High and low relay outputs reversed
D-Built-in Alarm Lights & Reset Switches
LEFT SIDE RIGHT SIDE D-00 None None D-01 - Light "On" Above High S.P. D-02 Light "On" Below Low S.P. - D-03 Light "On" Below Low S.P. Light "On" Above High S.P. D-04 - High S.P. Reset Switch D-05 Low S.P. Reset Switch - D-06 Reset Switches both Low & High S.P.'s D-07 High S.P. Reset Switch w/Light "On" Above High S.P. D-08 Low S.P. Reset Switch w/Light "On" Below Low S.P. D-09 Low S.P. Reset Switch w/Light "On" Above High S.P. D-10 High S.P. Reset Switch w/Light "On" Below Low S.P. D-11 Light "On" Below High S.P. D-12 Light "On" Above Low S.P. D-13 NOT USED D-14 Light "On" Above High S.P. Single Switch Resets Both Latch Circuits
F-Special Features
F-00 Standard-NO SPECIAL FEATURES F-01 MR2 Tamperproof single set pt. MR4 Screwdriver adjustable Single set pt. F-02 Preset High/Adjustable Low set pt.'s F-03 Fixed Differential SP's F-04 Fixed Position single set pt. F-05 NOT USED F-06 Preset Low/Adjustable High set pt.'s F-07 Rear Terminal Board Safety Cover F-08 MR2 Tamperproof double set pt. MR4 Screwdriver Adjustable double set pt. F-09 MR4 Single Low set pt. with left hand knob MR2 Single Low set pt. F-10 Dust & Splash Resistant
H-Latching Modes
H-00 Standard High and Low Latching Provided H-01 High Latching Only H-02 Low Latching Only H-03 No Latching Provided H-04 High Relay Unlatches Low Set Low Relay Unlatches High Set H-05 thru H-09 NOT USED H-10 Delayed Latch, Both Set Points H-11 Delayed Latch, High Set Points Only H-12 Delayed Latch, Low Set Point Only
J-Additional Options*
J-01 Thermistor Bridge Input J-02 RTD Bridge Input J-03 AC current Measurement (direct) J-04 Thermocouple Input J-05 DC Millivolt Meter J-06 Multiple Thermocouple Average J-07 NOT USED J-08 AC Motor Load J-10 Megohmmeter J-11 4-wire RTD Input J-12 DC Microammeter J-13 Adj. Freq. Current Source J-14 +- 15VDC Output J-15 Input Signal Suppression J-21 Analog DC Output
* with some J-options input power is limited to either 115 or 230VAC
Model Identification
MR __ - __ __ - __ __ - __ __
first space = model "2" second space = set points "1"(single) "2" (double) third space = size "3" (3 inch) "4" (4 inch) fourth & fifth spaces = case type & mounting "05" MR2 Surface Mount "06" MR2 Behind Panel Mount "07" MR4 Surface Mount "08" MR4 Behind Panel Mount All above are CENTURION style "13" MR4 QA Surface Mount sixth & seventh spaces = package type "00" Standard, complete unit "01"Optical element only "02" Separate Control PackageEXAMPLE: MR 4 - 2 4 - 0 7 - 0 1Model MR4, Double Set Point, 4" Size Centurion surface mount, Optical Element Only
Mod Center/Distributor Service
For fast delivery of our most popular models in quantities of 25 or less per order, contact your local Beede Meter Modification/Distribution Center. In addition to off-the-shelf availability of meter relays, the Mod Center can provide you with application assistance and design special meter scales or ranges to suit your particular need.
|
|