Digiflow FlowX3 Ultra Low Flow Sensors Type ULF


The Type ULF Ultra Low Flow Sensors are available in two flow ranges. They contain a transducer and a four blade paddle wheel rotor with a permanent magnet inside each blade. A square wave output signal is generated with frequency proportional to rate of rotor rotation and flow velocity. This pulse output is normally fed to a FlowX3 flow monitor/transmitter, blind transmitter, batch controller or adjustable flow switch. It can also be fed to other brand instruments or PLC’s.

Two types of sensors are available, Hall Effect which requires a 5 to 24 VDC power supply and Reed Effect which have a volt-free contact. Reed Effect is required with the battery powered flow monitor. Hall Effect signals may be transmitted up to 300 meters (984 ft.) without the need for conditioning whereas Reed Effect signals may be transmitted up to 16 m (52.5 ft.) without conditioning.

Polyoxymethylene (POM) Version

Sensor Body: POM
Rotor: POM
Shaft: Corepoint®†
O-Ring: Viton®
Connections: Inline 1/4" BSP male threaded
Flow Ranges: ULF01 Model: 1.5 to 100 l/h (0.0066 to 0.44 gpm)
ULF03 Model: 6 to 250 l/h (0.0264 to 1.10 gpm)

ECTFE Version

Sensor Body: ECTFE (Halar®)
Rotor: ECTFE (Halar®)
Shaft: Sapphire
Bearings: Sapphire
O-Ring: Viton® or Kalrez®
Connections: Inline 1/4" BSP male threaded
Flow Ranges: ULF01 Model: 1.5 to 100 l/h (0.0066 to 0.44 gpm)
ULF03 Model: 6 to 250 l/h (0.0264 to 1.10 gpm)

†Corepoint® is a steel alloy.

Type ULF Ultra Low Flow MeterData Page

Digiflow, FlowX3, Ultra Low, Flow Sensors, Type ULF, Chemline




















Digiflow, FlowX3, Ultra Low, Flow Sensors, Type ULF, Chemline
Back to
Digiflow FlowX3

Digiflow, FlowX3, Ultra Low, Flow Sensors, Type ULF, Chemline
Back to
Flow Meters

Digiflow, FlowX3, Ultra Low, Flow Sensors, Type ULF, Chemline
Back to Canadian
Product Line

Digiflow, FlowX3, Ultra Low, Flow Sensors, Type ULF, Chemline
Back to
UK Product Line

Digiflow, FlowX3, Ultra Low, Flow Sensors, Type ULF, Chemline
Back to U.S.A.
Product Line