Process H2S and Sulphur Measurement
Systems
Components
Element Analysis
Wobbe Index and Calorimeters

Other Manufacturers

Kentron Systems Index
CDS Separation Systems
Expo Technologies
FMC Technologies
GM International Safety
Hobré Instruments
MPM Flowmeters
MTL Instrument
ProAnalysis
Sensorlink
Sentech AS
Siemens

Related Web Sites
www.kentron.ca

Process,H2S,Sulphur,MeasurementProcess H2S and Sulphur Measurement

 

Solutions for measurements from low ppb levels up to percent levels of H2S/Sulphur in gasses and liquids are available with design based on a long experience. Our solutions include a range of measurement technologies, in combination with suitable sample handling and calibration/validation systems.

 

H2S is a dipole molecule, and in the low ppb and ppm levels it is easily absorbed by the sample wetted parts in the sample handling system. Carry over of products from the process line into the sample line could occur with all the consequences of wrong H2S measurement.

 

As a result of the above, a correct design of the sample handling system is key to the success of the analyzing system. Our solutions are designed for your specific process conditions and based on more than 25 years of experience in this field.

 

Key features of our systems are:

 

• Sample take-off assemblies removing the liquid and particle carry over products from gas streams as close as possible to the process. Special • Multiphobic filters are developed to retain any process and particle liquid carry over to the sample lines, sampling system, and analyser,

• Selected sample wetted parts to minimise absorption of the low levels H2S,

• For liquid applications we offer low maintenance free particle and water removal systems,

• Analytical method is selected to meet your application requirements taking into account: Matrix and Phase diagram of your process stream, response time and accuracy, maintenance and availability,

• Validation and calibration facilities,

• Protective cabinets and shelters to meet your environmental/ambient condition,

• Analysers from selected manufactures with proven products and support.

 

Our applications include:

 

• Low ppb and ppm for catalyst protection to improve catalyst life and efficiencies,

• Pipeline and corrosion protection (natural gas and crude oil),

• Crude oil and Natural Gas production,

• Monitoring of H2S removal systems (scavenger, amine, caustic, solid absorber),

• Olefin and polymer production,

• CO2,

• LPG and LNG,

• Petroleum products, gasoline, kerosene, diesel, fuel oil,

• Emission reduction (Fuel-gas, Flare-Gas, Fuel-oil),

• A recent project covers the supply of H2S analysers on a 210.000 barrels/day crude oil production platform. These analysers are used in a SIL2 rated system to protect the export pipeline against H2S levels above 11 ppmWt.

 

Our services include: application reviews, designs, construction, testing, start-up, training and routine maintenance work.

We have partnerships with world leading companies in Process Analysis.

 

Application Sheet H2S and Total Sulfur Analyzers

 

Measuring Techniques and Measuring Principles for H2S and Total Sulfur

 

Process,H2S,Sulphur,MeasurementThere are several principles for measuring H2S- and Total S-concentration in liquids and in gasses:

 

• Colorimetric for H2S and Total Sulphur in combination with (catalytic) reduction,

• (Pulsed) Ultra Violet Fluorescence ((P)UVF) in combination with oxidation of Sulfur components,

• EDXRF (Energy Dispersive X-Ray Fluorescence),

 

We supply above technologies as stand-alone analyzers or integrated into a complete solution.

 

Measuring Principles:

Colorimetric (H2S Analyzer):

 

Features:

 

• Interference free (selective to H2S only),

• Detection limit < 1 ppb,

• No zero drift,

• 5 Seconds response on breakthrough,

• Linear response,

• Dual range capability,

• Up to 4 channel analysis,

• No other utilities than power supply required for ranges up to 100 ppm,

• ATEX and CE certified.

 

This colorimetric method is available with (catalytic) reduction for gasses and liquids to measure Total Sulphur in liquids and gasses at low ppb and ppm levels. In combination with High Temperature Sampling and Injection, this method is suitable for wet gas applications such as amine scrubbers, separators, etc.

 

(Pulsed) Ultra Violet Fluorescence ((P)UVF) (Total Sulfur):

 

The Pulsed UVF method is based on oxidation of the Sulphur to SO2 at 1100ºC, followed by UVF SO2 measurement. This method is suitable for gasses and liquids up to a Final Boiling Point (FBP) of 450ºC.

 

Features:

 

• Compliance to ASTM D5453, D2622 and ISO 20846 methods for Total Sulfur in petroleum products,

• Measuring range from 0 to 5 to thousands of ppm,

• Trace version for 0 to 2 ppm range,

• Response time: 3 to 5 minutes for 90% of new value,

• Comprehensive diagnostics,

• Automatic control of UV light intensity  enables long term stability,

• ATEX and CE certified.

 

EDXRF (Energy Dispersive X-Ray Fluorescence) (Total Sulfur):

 

The EDXRF method is measuring the Total Sulfur content in liquids without any conversion. It is a direct measurement of the Sulfur atom in any matrix.

 

The EXDRF method is especially suitable for liquid applications with a high final boiling point (FBP).

 

Features:

 

• Concentration above 10 ppm to percent level [S],

• True online analysis, measures average concentration over the measuring time,

• No oxygen is required, requires only inert purge gas for explosion proof operation,

• No matrix correction required,

• For higher viscosities a heated sample cell is available,

• No critical moving parts, minimum maintenance,

• No high temperature components,

• No consumabels,

• The X-ray source is an X-ray tube; the radiation is stopped when the power is switched off,

• ATEX classification, NEC purge available,

• CE certified.

 

Other analytical methods:

 

In some cases our solutions require other analytical methods to meet your specific requirements.

 

Hobré Instruments has successfully supplied the Gas Chromatography method as well as the Tuneable Diode Laser method (TDL) in the oil and gas industry.

 

Gas Chromatography (GC) Method (H2S Analyzer):

 

The GC method is selected for specific sulphur components in gasses and liquids. H2S analysis in gasses in the range of 0 to 20 ppm and above is successfully done with the Yokogawa GC, model C1000 Mark II, using a Thermal Conductivity Detector (TCD) which eliminates the need for Hydrogen as utility gas. Cycle times of 3 minutes can be achieved of gasses with hydrocarbon and water dewpoints up to 80ºC at 1 barg.

The GC-method is successfully applied for H2S and mercaptans in crude oil with the use of a stripping unit.

 

Tuneable Diode Laser (TDL-method) (H2S Analyzer):

 

This method employs a laser spectroscopy technique that measures trace amounts of H2S in gasses. The TDL method is an upcoming technology with low cost of ownership for the applications in the oil and gas industry.

 

Hobré Instruments has a partnership with a leading manufacturer in TDL technology.

 

The combination of TDL technology with our application experience offers a total solution with low cost of ownership; high reliability and fast response.

 

Application Sheet H2S and Total Sulfur Analyzers


 

  • MTL Instrument |
  • Sentech AS |
  • Siemens |
  • MPM |
  • Expo Technologies | Designed By Panther Marketing & Design