Megablocks,DIN Rail,Mounted,Wiring,Hubs,MTL,InstrumentsMegablocks DIN Rail Mounted Wiring Hubs From MTL Instrument

  • Kentron Systems Index
  • About Kentron Systems
  • New Products
  • Manufacturers Represented
  • Contact Us

Process Controls Index
Process Controls Index

Kentron Systems Index
Kentron Systems Index

MTL Products
MTL Products Index

IS Digital Indicators
Fieldbus Displays
MTL660
MTL646/647

IS Barriers/Isolators
Intrinsic Safety Zener Barriers
MTL7700
MTL700
Intrinsic Safety Isolators
MTL2000
MTL4000
MTL4500
MTL5000
MTL5500
MTL (SR) Series
MTL E-Series
Configuration Tools & Software

Process I/O
Process I/O
HART Interfacing
MTL830

Surge Protection
Power Surge Protection
Data & Signal Surge Protection
Fieldbus
Telecoms

Fieldbus
Filedbus Power Supplies
Filedbus Wiring Components
Filedbus Diagnostics
Filedbus Test Equipment

Industrial Ethernet
Industrial Ethernet

Other Manufacturers
Kentron Systems Index
CDS Separation Systems
Expo Technologies
FMC Technologies
GM International Safety
Hobré Instruments
MPM Flowmeters
MTL Instrument
ProAnalysis
Sensorlink
Sentech AS
Siemens

Related Web Sites
www.kentron.ca

Megablocks,DIN Rail,Mounted,Wiring,Hubs,MTL,InstrumentsMegablocks are DIN-rail mounted passive hubs designed for use in FOUNDATION fieldbus™ and Profibus-PA segments. They can connect 2, 4, 8, 10 or 12 field devices to the network trunk cable.

 

Megablocks minimize hand wiring and allow individual devices to be added to and removed from the segment without disrupting network communication. The SpurGuard™ option provides short circuit protection for the segment.

Hazardous area approvals permit installation in a variety of configurations in Zone 1 or 2 and Division 1 or 2. Within Zone 2 or Division 2, Megablocks may be installed as part of non-sparking (non-arcing) or energy-limited (non-incendive) circuits.

 

Additionally, SpurGuard™ versions have energy-limited spur connections, even if the trunk is classified as 'non-sparking', when fed for example from any of MTL's High Energy Trunk fieldbus power supplies.

Because a fieldbus segment must be terminated at the ends, why not use a Megablock with an integral terminator?

 

 
No SpurGuard™
With SpurGuard™ short circuit protection
Megablocks
General Purpose
Zone/Div 2 and Intrinsically Safe
General Purpose
Zone/Div 2
Zone/Div 1
Intrinsically Safe
Zone 1
EEx me
2 way
FCS-MB2
FCS-MB2-SG
F241
-
4 way
FCS-MB4
FCS-MB4-SG
F245
F245-XE
4 way with internal Terminator
-
FCS-MB4-SG-T
F247
F247-XE
8 way
FCS-MB8
FCS-MB8-SG
F251
F251-XE
8 way with internal Terminator
-
FCS-MB8-SG-T
F253
F253-XE
10 way
-
FCS-MB10-SG
-
-
10 way with internal Terminator
FCS-MB10-T
FCS-MB10-SG-T
F259
F259-XE
10 way with switched Terminator
-
F118
F261
-
12 way
-
FCS-MBT12-SG
-
-
12 way with internal Terminator
-
FCS-MBT12-SG-T
F271
F271-XE
12 way with switched Terminator
-
F215
-
-
Terminators
F100*
FBT1-IS
F100
FBT1-IS
FCS-MBT
FBT1-IS
FCS-MBT-XE

 

Megablock Series Literature

 

Product Code Description
Downloads
FCS-MBXFCS-MBX is intrinsically safe Megablock Series overview - outlines & approvals
Datasheet 

 

  • MTL Instrument |
  • Sentech AS |
  • Siemens |
  • MPM |
  • Expo Technologies | Designed By Panther Marketing & Design