Food Instruments, Food Instrumentation From Kobold Instruments

Measuring and Controling Instruments

Digital Hand-Held Thermometer Professional S. TD
Measuring range: -200 ... +1300 °C
Probe: NiCr-Ni
Accuracy: ± 0,2 °C of m. value
Supply: 9 V battery
Holding Function, min./max. /average -memory, °C/°F
Measuring memory, output (1 mV/°C), RS 232
Download Brochure

Low Volume Rotating Vane Variable Area Flowmeters DPL
Measuring range: 0,025-0,5 l/min ...1-25 l/min. water
Connection: G 1/2 male or hose connector
Material: Polypropylene
Max. pressure: 10 bar
Max. temperature: 70 °C
Linearity: ± 1%
Pulse output, frequency divider, analogue output,
Contacts, digital-/pointer indicator

Calorimetric Flow Switch KAL-K
Switching range: 4 cm/s ... 2 m/s
Conn.:: Tri Clamp
Material: brass, st.st.
Max. pressure: 100 bar
max. temperature: 80 °C
Repeatability: approx. 2 %
LED-chain, relay, analogue output

Ultrasonic Flowswitch LDU
Ultrasonic-Doppler principle
Range: 0,1-1 m/sec. water
Connection: G 1/2 for hygenic sleeve LZE
Material: st.st. 1.4305 / PEEK
Max. pressure: 10 bar
Max. temperature: 150 °C
Accuracy: ± 3% FS
Switch output, analogue output 4-20 mA
Download Brochure

Magnetic Inductive Variable Area Flowmeters/-monitor/-counter DMI
Measuring range:0-50 l/min...0-1200 l/min water
Connection:G 3/4...G 2 1/2 AG
Material: PEEK, PVDF, Electrode Hastelloy C
Max. pressure: 10 bar
Max.temperature:110°C
Accuracy:± 1,5 % of m. value (if Q>7 % of FS)
Output: pulse-/analogue output, digital display, totalizer

All St.St. Bourdon Tube P/G with Diaphragm Seal MAN-R
Range: -1 ... 0 bar up to 0...600 bar
Connection: hygenic connectzion DIN 11851, Triclamp,
Union nut (IDF-, APV-RJT-, or SMS-Norm), pipe diaphragm seal , diaphragm seal for homogenizing machines.
Housing material: st.st.
Housing diameter: 63, 100, 160 mm
Accuracy calss: 1,6 or 1,0
Option: contacts
Download Brochure

Digital Pressure Gauge with Diaphragm Seal MAN-S
Range: -1...0 up to 0...600 bar
Connection: hygenic connection DIN 11851, Triclamp,
Union nut (IDF-, APV-RJT-, or SMS-Norm), Pipe diaphragm seal, diaphragm seal f. homogenizing
machines.
Housing material: st.st.
Housing diameter: 63, 100 mm
Accuracy class: 0,5
Options: contacts, analogue output, RS 232, peak memory

Pressure Sensor Ceramic Element and Diaphr. Seal SEN
For relative pressure
Range: -1...0 bar up to 0 ...600 bar
Connection: hygenic connection DIN 11851, Triclamp,
Union nut (IDF-, APV-RJT-, or SMS-Norm), pipe diaphragm seal, diaphragm seal for homogenizing machines
Accuracy class: 0,5 or 1,0
Analogue output

Conductive Level Switch Compact , LNK-K
for conductive liquids (>10 mikroS)
Electrodes: 4 up to 2000 mm
Connection: G 1/2
hygenic mounting system (EHEDG)
hygenic DIN 11851, Tri-Clamp, weld on sleeve
Material: st.st. 1.4404, option: E-CTFE coating
Max. pressure: 10 bar
Max.temperature:150°C
Option: head mounted transmitter f. 1 contact
Download Brochure

Conductive Level Switch LNK
For conductive liquids (>10 mikroS)
Electrodes: 1-4 pcs, length: 4-2000 mm
Connection: G 1/2, G 1
hygenic mounting system (EHEDG)
hygenic DIN 11851, Tri-Clamp, weld on sleeve
Material: st.st. 1.4404, Option: C-CTFE coating
Max. pressure: 10 bar
Max.Temperatur:100°C (CIP 150 °C)
Options: head mounted transmitter f. 1 contact
Download Brochure

Liquid Level Switch NWS
For liquids
Contact: 1 Electronic switch
Connection:G 3/4, G1 male, 3/4 NPT, 1 NPT male,
TriClamp DIN 32676, hygenic DIN 11851
Material: st. st. 1.4408
Max. pressure:50 bar
Max.temperature:130°C (150 °C CIP-cleaning)
Viscosity: up to 5000 mm²/s

Microwave Level Switch LNM
As well for non conductive liquids
insensitive to foam and adhesions
Connection: G 1/2, M12x1,5;
hygenic mounting system (EHEDG)
hygenic DIN 11851, Tri-Clamp, weld on sleeve
Material: st.st. 1.4404 / PEEK
Max. pressure: 10 bar
Max. temperature: 100 °C (CIP 150°C)
Contact: Open Collector, PNP, 50 mA
Download Brochure

Capacitive Level Limit Switch LNZ
As well for non conductive liquids sensitive to foam, not for adhesions
Connection: G 1/2
hygenic mounting system (EHEDG)
hygenic DIN 11851, Tri-Clamp, weld on sleeve
Material: st.st. 1.4404 / PEEK
Max. pressure: 10 bar
Max. temperature: 100 °C (CIP 150°C)
Contact: Open Collector, PNP, 200 mA
Download Brochure

Continuous Level Probe LNP
Potentiometric principle
For viscous, pasted, strong adhessive medias
Measuring length: 40, 200, 300, 400 or 500 mm
Connection: G 1/2, G1 for hygenic sleeve LZE
Material: st.st. 1.4305 / PEEK
Max. pressure: 10 bar
Max. temperature: 120°C (short time 150 °C)
Output: 4-20 mA
Download Brochure

Hydrostatic Level Meter LPC
Capacitive measuring cell
Range: 0-2...0-40 m
Connection: G1 for hygenic sleeve LZE
Material: st.st. 1.4305, ceramic Aluminum oxide
Max.temperature: 100°C (with neck 150 °C)
Output: 4-20 mA
Download Brochure

Level Indicator for Hydrostatic Level Meters LPA
Electronic for hydrst. level meter LPC
Linearising f. different tank forms
Indication: 4, 5-digit LED
Dimensions: 96x48 mm
Input:2x 0(4)-20 mA, 3 control inputs
Output: 0(4)-20 mA, 1 alarm contact, 2 change over contacts
Option: sensor supply
Download Brochure

Stem Thermometer Nitrogen Filled TNS
Measuring range: -20 ... +40 up to 0 ... 600 °C
Connection: back or bottom G1/2... G1, 1/2" NPT...1" NPT, TriClamp, and so on
Housing Material: steel, aluminum or st. st.
Diameter of housing: 63, 80, 100,160 or 250 mm
Accuracy class: 1,0 or 1,6
Option: contacts, gliding pointer, oil filling

Capillary Thermometer Nitrogen Filled TNF
Measuring range: -20 ... +40 up to 0... 600 °C
Connection: back or bottom
G1/2... G1, 1/2" NPT...1" NPT, TriClamp, aso.
Housing Material: steel, aluminum or st. st.
Diameter of housing: 63, 80, 100,160 or 250 mm
Accuracy class: 1,0 or 1,6
Capillary connection: up to 100 m
Option: contacts, Max. pointer, oil filling
Predection Pipes for Thermometer TSH
Connection: G 1/2...G 1, welded 18 m...28 mm
Material: st. st.
Max. pressure: 25 bar



Digital Thermometer DTM
Measuring range: -30 ... +50 up to 0...400 °C
Connection: back or bottom
G1/2... G1, 1/2"... 1" NPT
Housing Material: st. st., back polyamides
diameter of housing: 100 mm
Accuracy class: 0,5
Option: anlaogue output, up to 2(4) contacts, peak memory, RS 232

Resistor Temperature Sensor Compact LTS-NK
Pt100, class A acc DIN IEC 751
Range: -50...+250 °C
Connection: G 1/2, M12 for Hygienic sleeve LZE
Material: st.st.
Max. pressure: 10 bar
Option: head mounted transmitter 4-20 mA, fast responding sensor tip
Download Brochure

Resistor Temp. Sensor LTS
Pt100, class A acc. DIN IEC 751
Range: -50...+250 °C
Connection: G 1/2, M12 for hygenic sleeve LZE
Material: st.st.
Max. pressure: 10 bar
Option: head mounted transmitter 4-20 mA, fast responding sensor tip, longer neck for higher temperatures
Download Brochure

Pipe Temperature Sensor for Reliable Dead-Zone-Free TWP
Measuring range:-20 ... +200 °C
Connection: Hygenic connection, Triclamp
Pipe: st. st. DN 15..DN 80
Sensor: Pt100
Head B or field housing
Download Brochure

Turbidity Meter LAT-N1
4-beam pulsed light method
Measuring range: 0,01...1000 TE/F
0,01 ... 500 EBC
Connections: DN 40, 50, 65, 80, 100
Material: st. st., PEEK
Max. pressure: 6 bar
Max. temperature: 0 ... 80°C (short-time 120°C)
Accuracy: +/- 1% FS
Output: 4...20 mA
Download Brochure

Inductive Conductivity Meter LAL
Range: 0-1000 mS/cm
Repeatability: 0,5% FS
4 ranges, free selectable
Temperature compensation
Max. temperature: 150 °C
Max. pressure: 10 bar
Output: 2 analogue outputs
Download Brochure

Turbidity Meter LAT-N2
Infrared-pulsed (absorbtions-)-method
Measuring range: 0...100%
Connections: DN 40, 50, 65, 80, 100
Material: st. st.
Max. pressure: 10 bar
Max. temperature: 0...90°C (short-time 120°C)
Accuracy:
Output: 0/4...20 mA
Download Brochure

Turbidity Meter LAT-N3
Infrared-reflect scattering method
Measuring range: 0...100%
Connection: G1/2
Material: st. st., PEEK
Max. pressure: 10 bar
Max. temperature: 0...125°C
Repeatability: 1% FS
Output: 4...20 mA, switching output: acktive output
Download Brochure

Digital Indicator without Power Supply LZA
Input: Pt100 (3-wire), 4-20 mA (current)
Material: st.st. 1.4305
Protectiont: IP 67
Download Brochure

Hygenic Mounting Systems LZE
EHEDG-and 3A-certified
Connection sensor: G 1/2, G 3/4, G1, M12x1,5
Connection prozess: weld on sleeve, ball sleeve, collar sleeve, Triclamp, varivent, clamp
Material: st.st. 1.4404
Max. pressure: 10 bar
Max. temperature: 250°C
Download Brochure

Hygenic Weld-in Pipes LZE-NR
EHEDG-and 3A-certified
Connection Sensor: G 1/2, G1, M12x1,5
Nom. Pipe size: DN 15...DN 80
Material: st.st. 1.4404
Max. pressure: 16 bar
Max. temperature: 250°C
Download Brochure