Low Volume,Flowmeter,Switch,Transmitter,Kobold Instruments

Low Volume Flowmeter, Switch, Transmitter From Kobold Instruments

Low Volume,Flowmeter,Switch,Transmitter,Kobold Instruments

KMI - Armored Low Flow Flowmeter/Switch/Transmitter

  • Measuring Range: 0.026 - 0.26 GPH ...6.6 - 66 GPH (water)
    0.15 - 1.6 SCFH ... 28 - 282 SCFH (air)
  • Fitting: 1/4" NPT, 3/8" NPT
  • Material: SS
  • Max. pressure: 2320 PSIG
  • Max. temperature: 300°F
  • Accuracy class: +/-4% FS
  • Option: analog output, contacts
Low Volume,Flowmeter,Switch,Transmitter,Kobold Instruments

KSK - All Plastic Low Flow Flowmeter & Switch

  • Measuring Range: 0.006-0.05 GPM....0.44-4.4 GPM (Water),
    0.06-0.27 SCFM to 11.8-62 SCFM (Air)
  • Fitting: G 3/4... G 11/2 male,
    3/8"-1" NPT
  • Material: trogamid, polysulfone
  • Max. pressure: 145 PSIG
  • Max. temperature: 140 °F
  • Accuracy class: ± 4% of FS
  • Options: contact, air scale
Low Volume,Flowmeter,Switch,Transmitter,Kobold Instruments

KSR/SVN - Low Volume Flow Switch for Liquids or Gases

  • Switching Range:0.03 - 4 GPH (water)
    0.1-13 SCFH (air)
  • Connection: 1/4 NPT female
  • Material: SS 1.4305
  • Max. pressure: 230 PSIG
  • Max. temperature: 160°F
  • Contact: proximity switch or reed contact
Low Volume,Flowmeter,Switch,Transmitter,Kobold Instruments

KDG/ KDF - Low Volume Glass Tube Flowmeter

  • Measuring Range: 0.25 - 2.5 l/h ...16 - 160 l/h (KDF) (water)
    0.5 - 5 l/h...430 - 4300 l/h (KDG) (air)
  • Fitting: 1/4" NPT female
  • Material: brass, SS
  • Max. pressure: 230 PSIG
  • Max. temperature: 210°F
  • Accuracy class: +/-2.5 % FS
  • Option: contacts
Low Volume,Flowmeter,Switch,Transmitter,Kobold Instruments

SWK - Flowmeters and Switches

  • Measuring Range: 0.05-0.1...13-24/min.water
  • Fitting: G 1/2 female
  • Material: brass, SS or PVC
  • Max. pressure: 3600 PSIG
  • Max.temperature: 212°F
  • Accuracy: +/- 4 % FS
Low Volume,Flowmeter,Switch,Transmitter,Kobold Instruments

KSV - Economical Micro Flowmeters

  • Measuring Range: 0.04 - 0.4 GPH ... 2 - 20 GPH (water)
    0.3 - 3 SCFH... 10 - 100 SCFH (air)
  • Fitting: 1/8" NPT female
  • Material: polysulfone/brass, polysulfone/st. st.
  • Max. pressure: 100 PSIG
  • Max. temperature: 130 °F (polycarbonate); 250 °F (polysulfone)
  • Accuracy: +/-6 % FS
  • Option: needle valve
Low Volume,Flowmeter,Switch,Transmitter,Kobold Instruments

KDK - Low Volume/All-Metal Flowmeters

  • Measuring Range: 0.08-0.8 to 2.5-25 GPH water
    0.2-2 to 13-130 SCFH air
  • Fitting: 1/4" NPT
  • Material: SS wetted parts
  • Max. pressure: 1850 PSIG
  • Max.temperature: 350°F
  • Accuracy class: ±2.5% FS
  • Option: analog output, contact
Low Volume,Flowmeter,Switch,Transmitter,Kobold Instruments

KFR - Acrylic Flowmeters for Liquids or Gases

  • Measuring Range: 0.2-2 GPH...2-20 GPM water
    0.1-1 SCFH...10-100 SCFM air
  • Fitting: 1/8... 1 NPT female
  • Material: acrylic
  • Max. pressure: 100 PSIG
  • Max. temperature: 150 °F
  • Accuracy: ± 2 % FS
Low Volume,Flowmeter,Switch,Transmitter,Kobold Instruments

KDP - Miniature Armored Flowmeters & Switch

  • Measuring Range: 0.08-0.8 GPM to 2.5-25 GPH water
    0.2-2.0 SCFH to 13-130 SCFH air
  • Accuracy: ±4% FS
  • Fitting: 1/4" NPT SS
  • Max. Pressure: 1885 PSIG
  • Max. Temperature: 302°F
Low Volume,Flowmeter,Switch,Transmitter,Kobold Instruments

REL-6 - Instrinsically Safe Relay/Power Supply

  • Supply Voltage: 120 VAC, + 5/-15%, 45-60 Hz
  • Power Consumption: 3.5 VA (approx.)
  • Maximum Relay (SPDT) Output
  • AC Rating: 250 VAC 4 A 500 VA (cos Ø = 0.7)
  • DC Rating: 110 VDC/0.2 A
    60 VDC/0.6 A
    24 VDC/4.0 A
  • Switching Frequency: 10 Hz Max