Frigid-X™ Cabinet Panel Coolers And Cabinet Enclosure Coolers

Frigid-X,Cabinet Panel Coolers,Cabinet Enclosure Coolers,Panel,Cabinet,Coolers,Enclosure,Cabinet CoolersFrigid-X Cabinet Panel Coolers and Cabinet Enclosure Coolers for electronic control panels provide a low cost method of both purging and cooling electrical and electronic control panels by using a stainless steel vortex tube to create cold air from ordinary compressed air.

Unlike many of our competitors all of the our Frigid-X Cabinet Panel Coolers and Cabinet Enclosure Coolers are stainless steel, not just the vortex tube for longer life and flexible use. Frigid-X Cabinet Panel Coolers and Cabinet Enclosure Coolers are compact and can be installed in minutes through a standard electrical knockout. There are virtually no moving parts.

Frigid-X Cabinet Panel Coolers and Cabinet Enclosure Coolers are ideal for all NEMA Type 12 (IP52), NEMA Type 3R (IP14) and NEMA Type 4-4X (IP56) rated panels. Prevent downtime due to overheating electric and electronic control panels and cabinets.

Frigid-X,Cabinet Panel Coolers,Cabinet Enclosure Coolers,Panel,Cabinet,Coolers,Enclosure,Cabinet Coolers
Frigid-X,Cabinet Panel Coolers,Cabinet Enclosure Coolers,Panel,Cabinet,Coolers,Enclosure,Cabinet Coolers
 

Frigid-X™ Cabinet Panel Coolers And Cabinet Enclosure Coolers - Advantages:

  • Low in cost compared to others

  • No moving parts

  • Eliminate fans, blowers and filters

  • Quiet

  • Superior design and performance

  • Maintenance free operation

  • Mounts in a standard electrical knockout

  • Made of durable stainless steel and metal arts - no cheap plastic parts

  • Cooling capacities to 2800 BTU/hour per unit

  • Maintain NEMA Type 12 (IP52), NEMA Type 3R (IP14) and NEMA Type 4-4X (IP56) integrity

  • Control and stabilize the temperature and humidity inside the enclosure

  • No CFC's or HCFC's

  • Eliminate circuit drift, nuisance drifting and dirt

  • Provide washdown protection (NEMA Type 4-4X (IP56)

Frigid-X™ Cabinet Panel Coolers and Cabinet Enclosure Coolers - Applications:

  • Programmable Controllers

  • System Control Cabinets

  • CCTV Cameras

  • Motor Control Centers

  • Relay Panels

  • CNC Machine Controls

  • Computer Panels

  • Laser Housing Enclosure Cooling

  • Electronic Scale Cooling

  • Modular Control Centers

  • Food Service Equipment Controls

Four Types of Frigid-X™ Cabinet Panel Coolers To Choose From:

  • Frigid-X™ Cabinet Panel Coolers NEMA Type 12 (IP-52) For Electronic Control Panels for General use in industrial environments where no direct liquid spray is applied to the unit. Stainless steel construction to hold up in corrosive environments.

  • Frigid-X™ Cabinet Panel Coolers NEMA Type 3R (IP-14) For Electronic Control Panels for Outdoor Use. Stainless steel to hold up to rain, snow, humidity and general outdoor use.

  • Frigid-X™ Panel Coolers NEMA Type 4-4X (IP-56) For Electronic Control Panels - splash resistant, for use in wash down environments as well as outdoor use. Unique patent pending design for secure water tight protection. Stainless steel for food service and corrosive environments. Stainless steel also provides for long life in wet environments and for outdoor use.

  • Frigid-X™ Panel Coolers NEMA Type 4-4X-316L (IP-56) For Electronic Control Panels – all external exposed surfaces are of 316L and ideal for pharmaceutical industry and extreme corrosive environments where 303/304 stainless steel is not adequate. As with the NEMA Type 4-4x units, the cooler is splash resistant, for use in wash down environments as well as outdoor use. Unique patent pending design for secure water tight protection. 316L Stainless steel for pharmaceutical grade, food service and extreme corrosive environments. Stainless steel also provides for long life in wet environments and for outdoor use.

Note: Always question non-approved units used on electrical enclosures
to assure that your panels are not damaged by inferior products.

Cabinet Enclosure Cooler ( Panel Coolers Air Conditioner) - All Metal Parts,
Stainless Steel Body, Quiet - Under 70dBA, Tests Show Frigid-X™ Constantly Quieter Than Competition!

Frigid-X™ Cabinet Panel Coolers and Cabinet Enclosure Coolers - Operation:

Filtered, compressed air enters the cabinet enclosure cooler and through the vortex tube component. The air is split into two streams, one hot and one cold.

The muffled hot air from the vortex tube is expelled through the top of the air conditioner. The cold air is directed into the enclosure through the cold air distribution hose. Hot air inside the enclosure rises and exits to atmosphere via the air exhaust at a slight positive pressure. The enclosure is both purged and cooled with clean air. No outside air enters the enclosure.

Specifications:

Contact Nex Flow for assistance in sizing cabinet enclosure cooler - Frigid-X series.
Below see Sizing Specifications.

MODEL NO.

VERSION

BTU/Hr. cooling*
(WATTS)

61008A

NEMA Type 12 (IP-52) Continuous Operation

580 (170)

61015A

NEMA Type 12 (IP-52) Continuous Operation

1100 (322)

61025A

NEMA Type 12 (IP-52) Continuous Operation

1800 (527)

61030A

NEMA Type 12 (IP-52) Continuous Operation

2100 (615)

61040A

NEMA Type 12 (IP-52) Continuous Operation

2900 (849)

     

63008A 

NEMA Type 12 (IP-52) on-off control 

580 (170) 

63015A

NEMA Type 12 (IP-52) on-off control

1100 (322)

63025A

NEMA Type 12 (IP-52) on-off control

1800 (527)

63030A

NEMA Type 12 (IP-52) on-off control

2100 (615)

63040A

NEMA Type 12 (IP-52) on-off control

2900 (849)

     

61008R

NEMA Type 3R (IP-14) Continuous Operation


580 (170)

61015R

NEMA Type 3R (IP-14) Continuous Operation

1100 (322)

61025R

NEMA Type 3R (IP-14) Continuous Operation

1800 (527)

61030R

NEMA Type 3R (IP-14) Continuous Operation

2100 (615)

61040R

NEMA Type 3R (IP-14) Continuous Operation

2900 (849)

     

63008X

NEMA Type 3R (IP-14) on-off control

580 (170))

63015X

NEMA Type 3R (IP-14) on-off control

1100 (322)

63025X

NEMA Type 3R (IP-14) on-off control

21800 (527)

63030X

NEMA Type 3R (IP-14) on-off control

2100 (615)

63040X

NEMA Type 3R (IP-14) on-off control

2900 (849)

     

61108X

NEMA Type 4-4X (IP-66) Continuous Operation

580 (170)

61115X

NEMA Type 4-4X (IP-66) Continuous Operation

1100 (322)

61125X

NEMA Type 4-4X (IP-66) Continuous Operation

1800 (527)

61130X

NEMA Type 4-4X (IP-66) Continuous Operation

2100 (615)

61140X

NEMA Type 4-4X (IP-66) Continuous Operation

2900 (849)

     

63108X

NEMA Type 4-4X (IP-66) on-off control

580 (170))

63115X

NEMA Type 4-4X (IP-66) on-off control

1100 (322)

63125X

NEMA Type 4-4X (IP-66) on-off control

21800 (527)

63130X

NEMA Type 4-4X (IP-66) on-off control

2100 (615)

63140X

NEMA Type 4-4X (IP-66) on-off control

2900 (849)

     
60115X 316 L Stainless Steel NEMA Type 4-4X (IP-66) on-off control (customer supplies own filter)** 1100 (322)
60125X 316 L Stainless Steel NEMA Type 4-4X (IP-66) on-off control (customer supplies own filter)** 21800 (527)
60130X 316 L Stainless Steel NEMA Type 4-4X (IP-66) on-off control (customer supplies own filter)** 2100 (615)
60140X 316 L Stainless Steel NEMA Type 4-4X (IP-66) on-off control (customer supplies own filter)** 2900 (849)
     
** In 316 environments normally customers will have special filtration systems for such environments already.
     

*Cooling effect based on 95 F temperature inside cabinet, 100 PSIG (6.9 BAR) compressor inlet pressure, and 70ºF (21ºC) inlet temperature. BTU/hr. figures rounded to nearest 100 BTU/hr (1 WATT).

All Continuous Operation models include the cooling unit, filter with auto drain and cold air distribution kit.

All On-Off control units include the cooling unit, filter with auto drain, cold air distribution kit, solenoid valve and thermostat.

Use Our Side Mounts For Tight Spaces

Cabinet Cooling,Solutions,Frigid-X,Cabinet Panel Coolers,Cabinet Cooling Solutions,Cabinet,Coolers,Panel CoolersCabinet Cooling Solutions With Frigid-X™ Cabinet Panel Coolers are normally mounted on the top of the enclosure but if space does not permit, you can use our Side Mount Kit. Made of stainless steel for NEMA Type 12 (IP52), NEMA Type 3R (IP14) and NEMA Type 4-4X (IP56) environments, they are designed for use with all Nex Flow Cabinet Cooling Solutions With Frigid-X™ Cabinet Panel Coolers. Two sizes are available, one for coolers 85CFM and under capacity and the other forlarger sizes. Slim design to minimize space even when mounted on the side of a panel.

Easy mount Side Mount Kit is available for smal and medium size panel coolers to allow mounting to the side of an enclosure if space prevents top mounting. It is a "plug and play" system.

Adjustable Air Amplifier, Adjustable, Air, Amplifier, Nex Flow


Nex Flow Air Products Corp.