I.S.-1 is the modular decentralized
Remote I/O for process applications with Ex signals.
Intrinsic safety (I.S.) is one of the main requirements of a field bus
system in the process industry. With our new I.S.-1 product, we
are staying on the leading edge of field bus technology.
Save time, space, and money with I.S.-1.
I.S.-1
completely replaces the equipment used between I.S. field devices and
the automation system. Local terminals boxes, main cables, marshaling
cabinets, I.S. interface and their individual connections are now a
thing of the past.
I.S.-1 gives you the choice.
Decentralized
I.S.-1 field stations are fitted locally in the hazardous area and of
course, I.S.-1 can also be used in the control room. As a node
in the field bus network, I.S.-1 ensures fast and safe communication
with automation systems. The I.S. interface is integral
in each and every case.
I.S.-1 is based on years of experience.
We
pioneered remote I/O technology in hazardous areas - we invented field
stations for Zone 1 over 10 years ago. And the expertise gained
with our ICS MUX intrinsically safe field bus system is now incorporated
in the brand new I.S.-1
The PowerBus - the strength of a powerful
idea
A
central power module provides the necessary power. The I/O modules
are simply attached and supplied from the PowerBus. This simplifies
designing and installing a field system. Nothing impedes subsequent
extensions.
High availability from scaleable redundancy
We
provide tailor-made solutions for your application and requirements.
All critical parts can be configured individually or together as "hot
standby redundancy": field bus cable, bus module, power module.
Even the internal data bus is duplicated.
Two zones, one system design
You'll
find the right configuration for every zone with just one continuous,
uniform system design. In zone 2, I.S. and non-I.S. signals can
be mixed. We even have a solution for applications in Zone 1 which
are not intrinsically safe - for example, Ex d transmitters and Ex m
valves. Even more, I.S.-1 can replace marshaling cabinets and
I.S. interface in the control room.
Hot swap - it couldn't be simpler!
Each
module can be replaced during operation, even in the Zone 1 hazardous
area. All of the parameters required by a replacement module are
automatically reloaded. Downtimes and repair times are reduced
to a minimum.
Diagnosis: perfect health
The
service bus also allows a configuring and diagnostic tool to be connected,
enabling you to localize errors easily, quickly, and accurately.
The three-stage diagnosis covers:
- field
stations with central modules for power supply and field bus connection.
- I/O
modules
- individual
signals (wire breakage and short circuit for inputs and outputs, deviation
from the measuring range, etc.) or the various I/O modules.
- All
inputs and outputs can be simulated to test the automation functions.
|