In Line Display Setra Model 880

In,Line,Display,Setra,Model,880SETRA-IN-LINE-DISPLAY (SID) This small, low-powered digital display can be installed in-line between a Setra pressure transducer (or transmitter), the user's application and power supply.

Features

  • Convenient local display
  • Small Size
  • Low power consumption
  • 3 1/2 digit LCD display
  • Designed to be wired in-line
  • Pressure displayed in engineering units
  • Use with voltage or current input devices
  • Optional Bayonet Connectors
Model 880 Specifications
Display
Display:
3 1/2 (1999)
Elevated Zero:
35% of Full Scale Range (max.)
Type:
7 Segment LCD
Polarity:
Automatic (-) displayed
Decimal Point:
3 position, jumper selected
Overload:
Three lower digits blank for readings
Accuracy:
0.25% of reading ±1 count
Environmental
Operating Temperature:
32°F to 140°F (0°C to 60°C)
Storage Temperature:
-40°F to 158°F (-20°C to 70°C)
Temperature Coefficient:
215ppm/°F (120ppm/°C)
Electrical Data
Common Mode Voltages:
0 to 5 VDC
Input Impedance:
100k ohms
Voltage Excitation:
At 7 VDC = 1.5 mA
At 32 VDC = 15 mA
Over Voltage Protection:
40 VDC or peak AC continuous (Prevents damage to S.I.D. if miswired)
When Used with Transducer Voltages (3 or 4 wire)
Voltage Inputs:
0 - 5 VDC
1 - 6 VDC
0.1 - 5.1 VDC
0.2 - 5.2 VDC
When Used with Transmitters (4-20 mA)
Current Inputs:
4 - 20 mA (two wire self-powered)
Loop Voltage Drop:
5.9 VDC max.
Overload:
70 mA forward, 80 mA reverse

* Specifications subject to change without notice.