The
Aysix Hydra SX40 is designed as a permanently installed Fixed
Doppler Flow Meter. Its large backlit graphics display provides
excellent visibility even in poorly lit environments. As well
as flow rate and flow total, a flow trend is available to quickly
analyze flow over a period of time.
This is especially useful for analyzing pump cycling activity.
Standard outputs include 4-20mA, RS232 serial interface and
up to four programmable relays. The flowmeter also incorporates
a 90,000-point data logger.
Fixed Doppler Flow Meter Specifications:
| Flow
Range |
+/- 0.2 to 32
ft/s (+/- 0.06 to 10 m/s) |
| Accuracy
|
+/- 1% of total
error band |
| Linearity |
0.1% of scale,
digital output |
| Pipe
Size |
0.5 in. to 200
in. (12mm to 5m) |
| Enclosure |
NEMA 4X (IP65) |
| Outputs |
4-20mA, RS232,
5 amp SPDT relay (up to 4) |
| Transmitter
Temperature |
-5ºF to
+140ºF (-20ºC to +60ºC) |
| Transducer
Temperature |
-40ºF to
+200ºF (-40ºC to +93ºC) |
|