Specifications
|
| Power Requirements: |
12/24 VDC
50/60 Hz ± 15%, 5VA |
| Output Relay: |
DPDT 10 Amp at 250 VAC |
Ambient Temperature
Electronics:
Probe: |
-40° to
+185°F (-40° to +85°C)
+250°F Delrin, +500°F Teflon |
| Pressure: |
500 PSI, ¾" Mount |
| Sensitivity
Setting: |
Adjustable Sensitivity to
< 1 Picofarad |
| Calibration: |
"Quick Set" Adjust
Single Turn Potentiometers |
| Fail-Safe: |
Switch Selectable High/Low |
| Time
Delay: |
Adjustable up to 10 seconds |
| Enclosure: |
Die Cast Aluminum
USDA Approved Powder Coat Finish |
| Conduit Entry: |
¾" NPT |
| Mounting: |
1 ¼" NPT or ¾"
NPT 316 SS |
| Pro Shield: |
Compensates For Material Build-up
On Sensing Probe |
| Approval Ratings: |
NEMA 4X, 5 and 12
|
| Status Indicator: |
Internal LED Indicates Material
In Contact With Probe |
| Probe Options:
|
Standard, Flush Mount, Flexible
Extension, Teflon Sleeved, Extended Shield, Stubby |